2019•Journal of Nuclear Engineering and Radiation ScienceRequires access

Experimental Demonstration of Safety During Extended Station Blackout in an Integral Test Loop of a Natural Circulation Boiling Water Reactor

Arun Kumar Nayak, Mukesh Kumar, A. K. Vishnoi, Vikas Kumar Jain, Dinesh Kumar Chandraker

Open publisher page 1 citations

Abstract

Decay heat removal for prolonged period of station blackout (SBO) is a safety concern of the nuclear reactors. Aftermath of Fukushima, safety evaluation (performance under severe conditions: stress test) of the reactors was carried out worldwide. It includes establishment of grace period of the reactors. Similar exercises for advanced heavy water reactor (AHWR) were also performed and the design of AHWR was established for its robustness against such events. Decay heat removal during extended SBO is such a condition to be qualified. In this regard, experiments in the integral test loop (ITL), a full scale test facility of AHWR, were conducted for continuous 7 days of extended SBO. Experiment was started with 6.8 MPa as the initial reactor pressure and decay heat removal was demonstrated for 7 days of SBO by passive means. It is observed that the pressure falls down to 1 MPa in 3 h. The design of AHWR was evaluated from safety critical aspects during such an event experimentally. During this event, the clad surface temperature was found to be well within safe limits of operations. As a result of this experiment, it can be concluded that the design of AHWR is capable to remove decay heat for 7 days of SBO with sufficient safety margins.

About this research paper

What this paper is about

Decay heat removal for prolonged period of station blackout (SBO) is a safety concern of the nuclear reactors. Aftermath of Fukushima, safety evaluation (performance under severe conditions: stress test) of the reactors was carried out worldwide. It includes establishment of grace period of the reactors. Similar exercises for advanced heavy water reactor (AHWR) were also performed and the design of AHWR was established for its robustness against such events. Decay heat removal during extended SBO is such a condition to be qualified. In this regard, experiments in the integral test loop (ITL), a full scale test facility of AHWR, were conducted for continuous 7 days of extended SBO. Experiment was started with 6.8 MPa as the initial reactor pressure and decay heat removal was demonstrated for 7 days of SBO by passive means. It is observed that the pressure falls down to 1 MPa in 3 h. The design of AHWR was evaluated from safety critical aspects during such an event experimentally. During this event, the clad surface temperature was found to be well within safe limits of operations. As a result of this experiment, it can be concluded that the design of AHWR is capable to remove decay heat for 7 days of SBO with sufficient safety margins.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Decay heat removal for prolonged period of station blackout (SBO) is a safety concern of the nuclear reactors. Aftermath of Fukushima, safety evaluation (performance under severe conditions: stress test) of the reactors was carried out worldwide. It includes establishment of grace period of the reactors. Similar exercises for advanced heavy water reactor (AHWR) were also performed and the design of AHWR was established for its robustness against such events. Decay heat removal during extended SBO is such a condition to be qualified. In this regard, experiments in the integral test loop (ITL), a full scale test facility of AHWR, were conducted for continuous 7 days of extended SBO. Experiment was started with 6.8 MPa as the initial reactor pressure and decay heat removal was demonstrated for 7 days of SBO by passive means. It is observed that the pressure falls down to 1 MPa in 3 h. The design of AHWR was evaluated from safety critical aspects during such an event experimentally. During this event, the clad surface temperature was found to be well within safe limits of operations. As a result of this experiment, it can be concluded that the design of AHWR is capable to remove decay heat for 7 days of SBO with sufficient safety margins.

Key concepts: Decay heat, Natural circulation, Blackout, Nuclear engineering, Boiling, Environmental science, Boiling water reactor, Thermal hydraulics

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental Demonstration of Safety During Extended Station Blackout in an Integral Test Loop of a Natural Circulation Boiling Water Reactor — Research Paper | ScholarLens