2019Journal of Refractive SurgeryRequires access

Determining the Potential Role of Crystalline Lens Rise in Vaulting in Posterior Chamber Phakic Collamer Lens Surgery for Correction of Myopia

Félix González-López, Rafael Bilbao‐Calabuig, Blas Mompean, Jorge Luezas, Julio Ortega‐Usobiaga, Vasyl Druchkiv

Open publisher page 70 citations

Abstract

PURPOSE: To assess the effect of crystalline lens rise (CLR) on postoperative vault in eyes implanted with a phakic Visian Implantable Collamer Lens (ICL) (STAAR Surgical Company, Monrovia, CA) with a central port for myopic correction. METHODS: Non-invasive Fourier-domain swept-source anterior segment optical coherence tomography was used for dynamic assessment of the study eyes under changing light conditions. Phakic intraocular lens (IOL) vault, anterior chamber depth (ACD), and CLR were recorded after surgery, and intra-eye differences were analyzed under scotopic and photopic ambient light conditions. Inter-group analysis and regression analysis were performed to investigate any potential correlation between these biometric variables. RESULTS: This retrospective observational study comprised 111 eyes (65 patients) implanted with a myopic Visian ICL. The mean change in CLR from mydriasis to miosis was 59 ± 60 µm (P < .001). The sample was further divided into four groups according to the CLR value in miosis: CLR < 0, 0 to 200, 201 to 350, and > 350 µm. A significant difference in central vault values was observed between the < 0 and > 350 µm groups, the 0 to 200 and 201 to 350 µm groups, and the 0 to 200 and > 350 µm groups (P < .05). Eyes with a high vault value (> 750 µm in mydriasis) had lower CLR values (P < .001) and higher ACD values (P < .001) than eyes with a low vault value (< 100 µm in miosis). The linear correlation observed was negative between CLR and ACD, positive between postoperative vault and ACD, and negative between postoperative vault and CLR (P < .001). CONCLUSIONS: CLR significantly affected anterior chamber depth and postoperative ICL vault. [J Refract Surg. 2019;35(3):177-183.].

About this research paper

What this paper is about

PURPOSE: To assess the effect of crystalline lens rise (CLR) on postoperative vault in eyes implanted with a phakic Visian Implantable Collamer Lens (ICL) (STAAR Surgical Company, Monrovia, CA) with a central port for myopic correction. METHODS: Non-invasive Fourier-domain swept-source anterior segment optical coherence tomography was used for dynamic assessment of the study eyes under changing light conditions. Phakic intraocular lens (IOL) vault, anterior chamber depth (ACD), and CLR were recorded after surgery, and intra-eye differences were analyzed under scotopic and photopic ambient light conditions. Inter-group analysis and regression analysis were performed to investigate any potential correlation between these biometric variables. RESULTS: This retrospective observational study comprised 111 eyes (65 patients) implanted with a myopic Visian ICL. The mean change in CLR from mydriasis to miosis was 59 ± 60 µm (P < .001). The sample was further divided into four groups according to the CLR value in miosis: CLR < 0, 0 to 200, 201 to 350, and > 350 µm. A significant difference in central vault values was observed between the < 0 and > 350 µm groups, the 0 to 200 and 201 to 350 µm groups, and the 0 to 200 and > 350 µm groups (P < .05). Eyes with a high vault value (> 750 µm in mydriasis) had lower CLR values (P < .001) and higher ACD values (P < .001) than eyes with a low vault value (< 100 µm in miosis). The linear correlation observed was negative between CLR and ACD, positive between postoperative vault and ACD, and negative between postoperative vault and CLR (P < .001). CONCLUSIONS: CLR significantly affected anterior chamber depth and postoperative ICL vault. [J Refract Surg. 2019;35(3):177-183.].

Why it matters

OpenAlex reports 70 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To assess the effect of crystalline lens rise (CLR) on postoperative vault in eyes implanted with a phakic Visian Implantable Collamer Lens (ICL) (STAAR Surgical Company, Monrovia, CA) with a central port for myopic correction. METHODS: Non-invasive Fourier-domain swept-source anterior segment optical coherence tomography was used for dynamic assessment of the study eyes under changing light conditions. Phakic intraocular lens (IOL) vault, anterior chamber depth (ACD), and CLR were recorded after surgery, and intra-eye differences were analyzed under scotopic and photopic ambient light conditions. Inter-group analysis and regression analysis were performed to investigate any potential correlation between these biometric variables. RESULTS: This retrospective observational study comprised 111 eyes (65 patients) implanted with a myopic Visian ICL. The mean change in CLR from mydriasis to miosis was 59 ± 60 µm (P < .001). The sample was further divided into four groups according to the CLR value in miosis: CLR < 0, 0 to 200, 201 to 350, and > 350 µm. A significant difference in central vault values was observed between the < 0 and > 350 µm groups, the 0 to 200 and 201 to 350 µm groups, and the 0 to 200 and > 350 µm groups (P < .05). Eyes with a high vault value (> 750 µm in mydriasis) had lower CLR values (P < .001) and higher ACD values (P < .001) than eyes with a low vault value (< 100 µm in miosis). The linear correlation observed was negative between CLR and ACD, positive between postoperative vault and ACD, and negative between postoperative vault and CLR (P < .001). CONCLUSIONS: CLR significantly affected anterior chamber depth and postoperative ICL vault. [J Refract Surg. 2019;35(3):177-183.].

Key concepts: Mydriasis, Ophthalmology, Miosis, Phakic intraocular lens, Medicine, Cataract surgery, Photopic vision, Cornea

Related papers

Back to paper searchBrowse research topicsOriginal source
Determining the Potential Role of Crystalline Lens Rise in Vaulting in Posterior Chamber Phakic Collamer Lens Surgery for Correction of Myopia — Research Paper | ScholarLens