Accuracy and Precision of a Point-of-Care HbA1c Test

William David Arnold, Kenneth Kupfer, Randie R. Little, Meera Amar, Barry Horowitz, Narendra Godbole, Monica Hvidsten Swensen, Yin Li, Richard C. San George

Open full text 24 citations

Abstract

BACKGROUND: Point-of-care (POC) hemoglobin A1c (HbA1c) testing has advantages over laboratory testing, but some questions have remained regarding the accuracy and precision of these methods. The accuracy and the precision of the POC Afinion™ HbA1c Dx test were investigated. METHODS: Samples spanning the assay range were collected from prospectively enrolled subjects at three clinical sites. The accuracy of the POC test using fingerstick and venous whole blood samples was estimated via correlation and bias with respect to values obtained by an NGSP secondary reference laboratory (SRL). The precision of the POC test using fingerstick samples was estimated from duplicate results by calculating the coefficient of variation (CV) and standard deviation (SD), and separated into its components using analysis of variance (ANOVA). The precision of the POC test using venous blood was evaluated from samples run in four replicates on each of three test cartridge lots, twice per day for 10 consecutive days. The SD and CV by study site and overall were calculated. RESULTS: = .99). The mean bias was -0.021% HbA1c (-0.346% relative) using fingerstick samples and -0.005% HbA1c (-0.093% relative) using venous samples. Imprecision ranged from 0.62% to 1.93% CV for fingerstick samples and 1.11% to 1.69% CV for venous samples. CONCLUSIONS: The results indicate that the POC test evaluated here is accurate and precise using both fingerstick and venous whole blood.

About this research paper

What this paper is about

BACKGROUND: Point-of-care (POC) hemoglobin A1c (HbA1c) testing has advantages over laboratory testing, but some questions have remained regarding the accuracy and precision of these methods. The accuracy and the precision of the POC Afinion™ HbA1c Dx test were investigated. METHODS: Samples spanning the assay range were collected from prospectively enrolled subjects at three clinical sites. The accuracy of the POC test using fingerstick and venous whole blood samples was estimated via correlation and bias with respect to values obtained by an NGSP secondary reference laboratory (SRL). The precision of the POC test using fingerstick samples was estimated from duplicate results by calculating the coefficient of variation (CV) and standard deviation (SD), and separated into its components using analysis of variance (ANOVA). The precision of the POC test using venous blood was evaluated from samples run in four replicates on each of three test cartridge lots, twice per day for 10 consecutive days. The SD and CV by study site and overall were calculated. RESULTS: = .99). The mean bias was -0.021% HbA1c (-0.346% relative) using fingerstick samples and -0.005% HbA1c (-0.093% relative) using venous samples. Imprecision ranged from 0.62% to 1.93% CV for fingerstick samples and 1.11% to 1.69% CV for venous samples. CONCLUSIONS: The results indicate that the POC test evaluated here is accurate and precise using both fingerstick and venous whole blood.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Point-of-care (POC) hemoglobin A1c (HbA1c) testing has advantages over laboratory testing, but some questions have remained regarding the accuracy and precision of these methods. The accuracy and the precision of the POC Afinion™ HbA1c Dx test were investigated. METHODS: Samples spanning the assay range were collected from prospectively enrolled subjects at three clinical sites. The accuracy of the POC test using fingerstick and venous whole blood samples was estimated via correlation and bias with respect to values obtained by an NGSP secondary reference laboratory (SRL). The precision of the POC test using fingerstick samples was estimated from duplicate results by calculating the coefficient of variation (CV) and standard deviation (SD), and separated into its components using analysis of variance (ANOVA). The precision of the POC test using venous blood was evaluated from samples run in four replicates on each of three test cartridge lots, twice per day for 10 consecutive days. The SD and CV by study site and overall were calculated. RESULTS: = .99). The mean bias was -0.021% HbA1c (-0.346% relative) using fingerstick samples and -0.005% HbA1c (-0.093% relative) using venous samples. Imprecision ranged from 0.62% to 1.93% CV for fingerstick samples and 1.11% to 1.69% CV for venous samples. CONCLUSIONS: The results indicate that the POC test evaluated here is accurate and precise using both fingerstick and venous whole blood.

Key concepts: Fingerstick, Medicine, Coefficient of variation, Point of care, Venous blood, Point-of-care testing, Accuracy and precision, Analysis of variance

Related papers

Back to paper searchBrowse research topicsOriginal source
Accuracy and Precision of a Point-of-Care HbA1c Test — Research Paper | ScholarLens