2019Advances in Civil Engineering MaterialsOpen access

Life-Cycle Cost and Life-Cycle Assessment Analysis at the Design Stage of a Fiber-Reinforced Polymer-Reinforced Concrete Bridge in Florida

Thomas Cadenazzi, Giovanni Dotelli, Marco Rossini, Steven Nolan, Antonio Nanni

Open full text 71 citations

Abstract

Abstract To support and promote the deployment of innovative technologies in infrastructure, it is fundamental to quantify their implications in terms of both economic and environmental impacts. Glass Fiber-Reinforced Polymer (GFRP) bars and Carbon Fiber-Reinforced Polymer (CFRP) strands are validated corrosion-resistant solutions for Reinforced Concrete (RC) and Prestressed Concrete (PC) structures. Studies on the performance of Fiber-Reinforced Polymer (FRP) reinforcement in seawater and salt-contaminated concrete have been conducted and show that the technology is a viable solution. Nevertheless, the economic and environmental implications of FRP-RC/PC deployment have not been fully investigated. This article deals with the Life-Cycle Cost (LCC) and Life-Cycle Assessment (LCA) analyses of an FRP-RC/PC bridge in Florida. The bridge is designed to be entirely reinforced with FRP bars and strands and does not include any Carbon Steel (CS) reinforcement. Furthermore, the deployment of seawater concrete in some of the elements of the bridge is considered. LCC and LCA analyses are performed at the design stage. Data regarding equipment, labor rates, consumables, fuel consumption, and disposal were collected during the construction phase, and the analysis was refined accordingly. The FRP-RC/PC bridge design is compared with a traditional CS-RC/PC alternative. Salient differences are discussed to determine the least-impactful solution from both an economic and environmental perspective.

About this research paper

What this paper is about

Abstract To support and promote the deployment of innovative technologies in infrastructure, it is fundamental to quantify their implications in terms of both economic and environmental impacts. Glass Fiber-Reinforced Polymer (GFRP) bars and Carbon Fiber-Reinforced Polymer (CFRP) strands are validated corrosion-resistant solutions for Reinforced Concrete (RC) and Prestressed Concrete (PC) structures. Studies on the performance of Fiber-Reinforced Polymer (FRP) reinforcement in seawater and salt-contaminated concrete have been conducted and show that the technology is a viable solution. Nevertheless, the economic and environmental implications of FRP-RC/PC deployment have not been fully investigated. This article deals with the Life-Cycle Cost (LCC) and Life-Cycle Assessment (LCA) analyses of an FRP-RC/PC bridge in Florida. The bridge is designed to be entirely reinforced with FRP bars and strands and does not include any Carbon Steel (CS) reinforcement. Furthermore, the deployment of seawater concrete in some of the elements of the bridge is considered. LCC and LCA analyses are performed at the design stage. Data regarding equipment, labor rates, consumables, fuel consumption, and disposal were collected during the construction phase, and the analysis was refined accordingly. The FRP-RC/PC bridge design is compared with a traditional CS-RC/PC alternative. Salient differences are discussed to determine the least-impactful solution from both an economic and environmental perspective.

Why it matters

OpenAlex reports 71 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract To support and promote the deployment of innovative technologies in infrastructure, it is fundamental to quantify their implications in terms of both economic and environmental impacts. Glass Fiber-Reinforced Polymer (GFRP) bars and Carbon Fiber-Reinforced Polymer (CFRP) strands are validated corrosion-resistant solutions for Reinforced Concrete (RC) and Prestressed Concrete (PC) structures. Studies on the performance of Fiber-Reinforced Polymer (FRP) reinforcement in seawater and salt-contaminated concrete have been conducted and show that the technology is a viable solution. Nevertheless, the economic and environmental implications of FRP-RC/PC deployment have not been fully investigated. This article deals with the Life-Cycle Cost (LCC) and Life-Cycle Assessment (LCA) analyses of an FRP-RC/PC bridge in Florida. The bridge is designed to be entirely reinforced with FRP bars and strands and does not include any Carbon Steel (CS) reinforcement. Furthermore, the deployment of seawater concrete in some of the elements of the bridge is considered. LCC and LCA analyses are performed at the design stage. Data regarding equipment, labor rates, consumables, fuel consumption, and disposal were collected during the construction phase, and the analysis was refined accordingly. The FRP-RC/PC bridge design is compared with a traditional CS-RC/PC alternative. Salient differences are discussed to determine the least-impactful solution from both an economic and environmental perspective.

Key concepts: Bridge (graph theory), Reinforced concrete, Materials science, Stage (stratigraphy), Structural engineering, Fiber, Life-cycle cost analysis, Fiber-reinforced concrete

Related papers

Back to paper searchBrowse research topicsOriginal source
Life-Cycle Cost and Life-Cycle Assessment Analysis at the Design Stage of a Fiber-Reinforced Polymer-Reinforced Concrete Bridge in Florida — Research Paper | ScholarLens