2019Journal of the Chinese Medical AssociationOpen access

Multisection computed tomography

Dan-dan Zhou, Pengfei Sun, Zhifang Jia, Wanan Zhu, Shi Guang, Boyu Kong, Haifeng Wang, Huimao Zhang

Open full text 7 citations

Abstract

BACKGROUND: As multisection spiral computed tomography (MSCT) have been extensively used, it is important to consider the amounts of doses the patients are exposed during a computed tomography (CT) examination. The aim of the current study was to summarize MSCT doses in Chinese patients to establish the diagnostic reference levels (DRLs). METHODS: Radiation dose metrics were retrospectively collected from 164,073 CT examinations via the Radimetrics Enterprise Platform. Radiation dose metrics (volume CT dose index [CTDIvol], dose-length product [DLP], effective dose [ED], and organ dose) and size-specific dose estimate (SSDE) were calculated for adults and children based on anatomic area and scanner type. RESULTS: The median CTDIvol and DLP values were highest in the head at 51.7 mGy (interquartile range [IQR], 33.2-51.7 mGy) and 906.5 mGy·cm (IQR, 582.4-1068.2 mGy·cm) and lowest in the chest at 7.9 mGy (IQR, 7.9-10.3 mGy) and 284.8 mGy·cm (IQR, 249.0-412.6 mGy·cm), respectively. The median SSDE values of chest and pelvis were 12.1 mGy (IQR, 10.8-14.1 mGy) and 36.3 mGy (IQR, 34.0-38.9 mGy), respectively. EDs for children were similar to adults except for an increased 1.5-, 0.77-, and 1.7-fold in the chest, neck, and pelvis, respectively (p < 0.001). Furthermore, radiation doses tended to increase with increasing slice number and decrease when exposure reduction techniques were used. CONCLUSION: Our findings provide a basis for the evaluation of CT radiation doses and evidence for establishment of DRLs in China.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: As multisection spiral computed tomography (MSCT) have been extensively used, it is important to consider the amounts of doses the patients are exposed during a computed tomography (CT) examination. The aim of the current study was to summarize MSCT doses in Chinese patients to establish the diagnostic reference levels (DRLs). METHODS: Radiation dose metrics were retrospectively collected from 164,073 CT examinations via the Radimetrics Enterprise Platform. Radiation dose metrics (volume CT dose index [CTDIvol], dose-length product [DLP], effective dose [ED], and organ dose) and size-specific dose estimate (SSDE) were calculated for adults and children based on anatomic area and scanner type. RESULTS: The median CTDIvol and DLP values were highest in the head at 51.7 mGy (interquartile range [IQR], 33.2-51.7 mGy) and 906.5 mGy·cm (IQR, 582.4-1068.2 mGy·cm) and lowest in the chest at 7.9 mGy (IQR, 7.9-10.3 mGy) and 284.8 mGy·cm (IQR, 249.0-412.6 mGy·cm), respectively. The median SSDE values of chest and pelvis were 12.1 mGy (IQR, 10.8-14.1 mGy) and 36.3 mGy (IQR, 34.0-38.9 mGy), respectively. EDs for children were similar to adults except for an increased 1.5-, 0.77-, and 1.7-fold in the chest, neck, and pelvis, respectively (p < 0.001). Furthermore, radiation doses tended to increase with increasing slice number and decrease when exposure reduction techniques were used. CONCLUSION: Our findings provide a basis for the evaluation of CT radiation doses and evidence for establishment of DRLs in China.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: As multisection spiral computed tomography (MSCT) have been extensively used, it is important to consider the amounts of doses the patients are exposed during a computed tomography (CT) examination. The aim of the current study was to summarize MSCT doses in Chinese patients to establish the diagnostic reference levels (DRLs). METHODS: Radiation dose metrics were retrospectively collected from 164,073 CT examinations via the Radimetrics Enterprise Platform. Radiation dose metrics (volume CT dose index [CTDIvol], dose-length product [DLP], effective dose [ED], and organ dose) and size-specific dose estimate (SSDE) were calculated for adults and children based on anatomic area and scanner type. RESULTS: The median CTDIvol and DLP values were highest in the head at 51.7 mGy (interquartile range [IQR], 33.2-51.7 mGy) and 906.5 mGy·cm (IQR, 582.4-1068.2 mGy·cm) and lowest in the chest at 7.9 mGy (IQR, 7.9-10.3 mGy) and 284.8 mGy·cm (IQR, 249.0-412.6 mGy·cm), respectively. The median SSDE values of chest and pelvis were 12.1 mGy (IQR, 10.8-14.1 mGy) and 36.3 mGy (IQR, 34.0-38.9 mGy), respectively. EDs for children were similar to adults except for an increased 1.5-, 0.77-, and 1.7-fold in the chest, neck, and pelvis, respectively (p < 0.001). Furthermore, radiation doses tended to increase with increasing slice number and decrease when exposure reduction techniques were used. CONCLUSION: Our findings provide a basis for the evaluation of CT radiation doses and evidence for establishment of DRLs in China.

Key concepts: Medicine, Interquartile range, Nuclear medicine, Radiation dose, Radiology, Pelvis, Computed tomography, Effective dose (radiation)

Related papers

Back to paper searchBrowse research topicsOriginal source
Multisection computed tomography — Research Paper | ScholarLens