2019Thermal ScienceOpen access

Development and experimental validation of a TRNSYS model for energy design of air-to-water heat pump system

Miklós Kassai

Open full text 8 citations

Abstract

The object of this research work is the comparison of the annual primary energy consumption of different types of heating systems, using two different calculation methods. The TRNSYS 18 software makes use of dynamic simulation, while the WinWatt software calculates according to the Hungarian implementation of EPBD (Decree No. 7/2006). There were differences in results which could be caused by the more precise calculation of the TRNSYS software. Differences were shown also in the weather data used by the two computer tools that had one of the most important effects on the results according this investigation. The number of heating degree days used by TRNSYS is 10% less, than that the Hungarian decree provides. Using the yearly measured energy consumption data given by the inhabitant of the investigated family house, the validation of the developed dynamic building energy simulation model by TRNSYS could be also achieved with good agreement.

Open-access reader

About this research paper

What this paper is about

The object of this research work is the comparison of the annual primary energy consumption of different types of heating systems, using two different calculation methods. The TRNSYS 18 software makes use of dynamic simulation, while the WinWatt software calculates according to the Hungarian implementation of EPBD (Decree No. 7/2006). There were differences in results which could be caused by the more precise calculation of the TRNSYS software. Differences were shown also in the weather data used by the two computer tools that had one of the most important effects on the results according this investigation. The number of heating degree days used by TRNSYS is 10% less, than that the Hungarian decree provides. Using the yearly measured energy consumption data given by the inhabitant of the investigated family house, the validation of the developed dynamic building energy simulation model by TRNSYS could be also achieved with good agreement.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The object of this research work is the comparison of the annual primary energy consumption of different types of heating systems, using two different calculation methods. The TRNSYS 18 software makes use of dynamic simulation, while the WinWatt software calculates according to the Hungarian implementation of EPBD (Decree No. 7/2006). There were differences in results which could be caused by the more precise calculation of the TRNSYS software. Differences were shown also in the weather data used by the two computer tools that had one of the most important effects on the results according this investigation. The number of heating degree days used by TRNSYS is 10% less, than that the Hungarian decree provides. Using the yearly measured energy consumption data given by the inhabitant of the investigated family house, the validation of the developed dynamic building energy simulation model by TRNSYS could be also achieved with good agreement.

Key concepts: TRNSYS, Work (physics), Software, Energy consumption, Environmental science, Software package, Simulation software, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and experimental validation of a TRNSYS model for energy design of air-to-water heat pump system — Research Paper | ScholarLens