Experiment data report for Semiscale Mod-3 Lower Plenum Injection Test S-07-8 (baseline test series). [PWR]
K.E. Sackett, R.L. Gillins, Doni Pack
Abstract
K.E. Sackett, R.L. Gillins, Doni Pack
Abstract
Recorded test data are presented for Test S-07-9 of the Semiscale Mod-3 baseline test series. This test is one of several Semiscale Mod-3 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-07-9 was conducted from initial conditions of 16.10 MPa and 559 K to investigate the response of the Semiscale Mod-3 system to a blowdown transient following a simulated double-ended offset shear of the broken loop cold leg piping. The specific objective of this test was to provide reference data to evaluate integral blowdown and reflood behavior during a 200% cold leg break with emergency core coolant (ECC) injection into the vessel lower plenum of the Mod-3 system. The purpose of this report is to make available the uninterpreted data from Test S-07-9 for future data analysis. The data, presented in the form of graphics in engineering units, have been analyzed only to the extent necessary to ensure that they are reasonable and consistent.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Recorded test data are presented for Test S-07-9 of the Semiscale Mod-3 baseline test series. This test is one of several Semiscale Mod-3 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-07-9 was conducted from initial conditions of 16.10 MPa and 559 K to investigate the response of the Semiscale Mod-3 system to a blowdown transient following a simulated double-ended offset shear of the broken loop cold leg piping. The specific objective of this test was to provide reference data to evaluate integral blowdown and reflood behavior during a 200% cold leg break with emergency core coolant (ECC) injection into the vessel lower plenum of the Mod-3 system. The purpose of this report is to make available the uninterpreted data from Test S-07-9 for future data analysis. The data, presented in the form of graphics in engineering units, have been analyzed only to the extent necessary to ensure that they are reasonable and consistent.
Key concepts: Boiler blowdown, Plenum space, Piping, Pressurized water reactor, Test data, Nuclear engineering, Boiling water reactor, Test (biology)