2019Polish Journal of RadiologyOpen access

Evaluation of various patient-, lesion-, and procedure-related factors on the occurrence of pneumothorax as a complication of CT-guided percutaneous transthoracic needle biopsy

Yassar Shiekh, Wani A. Haseeb, Imza Feroz, Feroze Shaheen, Tariq Gojwari, Naseer A. Choh

Open full text 20 citations

Abstract

Purpose To assess the influence of various patient-, lesion-, and procedure-related variables on the occurrence of pneumothorax as a complication of CT-guided percutaneous transthoracic needle biopsy. Material and methods In a total of 208 patients, 215 lung/mediastinal lesions (seven patients were biopsied twice) were sampled under CT guidance using coaxial biopsy set via percutaneous transthoracic approach. Incidence of post procedure pneumothorax was seen and the influence of various patient-, lesion-, and procedure-related variables on the frequency of pneumothorax with special emphasis on procedural factors like dwell time and needle-pleural angle was analysed. Results Pneumothorax occurred in 25.12% (54/215) of patients. Increased incidence of pneumothorax had a statistically significant correlation with age of the patient (p = 0.0020), size (p = 0.0044) and depth (p = 0.0001) of the lesion, and needle-pleural angle (p = 0.0200). Gender of the patient (p = 0.7761), emphysema (p = 0.2724), site of the lesion (p = 0.9320), needle gauge (p = 0.7250), patient position (p = 0.9839), and dwell time (p = 0.9330) had no significant impact on the pneumothorax rate. Conclusions This study demonstrated a significant effect of the age of the patient, size and depth of the lesion, and needle-pleural angle on the incidence of post-procedural pneumothorax. Emphysema as such had no effect on pneumothorax rate, but once pneumothorax occurred, emphysematous patients were more likely to be symptomatic, necessitating chest tube placement. Gender of the patient, site of the lesion, patient position during the procedure, and dwell time had no statistically significant relation with the frequency of post-procedural pneumothorax. Surprisingly, needle gauge had no significant effect on pneumothorax frequency, but due to the small sample size, non-randomisation, and bias in needle size selection as per lesion size, further studies are required to fully elucidate the causal relationship between needle size and post-procedural pneumothorax rate. The needle should be as perpendicular as possible to the pleura (needle-pleural angle close to 90°), to minimise the possibility of pneumothorax after percutaneous transthoracic needle biopsy.

Open-access reader

About this research paper

What this paper is about

Purpose To assess the influence of various patient-, lesion-, and procedure-related variables on the occurrence of pneumothorax as a complication of CT-guided percutaneous transthoracic needle biopsy. Material and methods In a total of 208 patients, 215 lung/mediastinal lesions (seven patients were biopsied twice) were sampled under CT guidance using coaxial biopsy set via percutaneous transthoracic approach. Incidence of post procedure pneumothorax was seen and the influence of various patient-, lesion-, and procedure-related variables on the frequency of pneumothorax with special emphasis on procedural factors like dwell time and needle-pleural angle was analysed. Results Pneumothorax occurred in 25.12% (54/215) of patients. Increased incidence of pneumothorax had a statistically significant correlation with age of the patient (p = 0.0020), size (p = 0.0044) and depth (p = 0.0001) of the lesion, and needle-pleural angle (p = 0.0200). Gender of the patient (p = 0.7761), emphysema (p = 0.2724), site of the lesion (p = 0.9320), needle gauge (p = 0.7250), patient position (p = 0.9839), and dwell time (p = 0.9330) had no significant impact on the pneumothorax rate. Conclusions This study demonstrated a significant effect of the age of the patient, size and depth of the lesion, and needle-pleural angle on the incidence of post-procedural pneumothorax. Emphysema as such had no effect on pneumothorax rate, but once pneumothorax occurred, emphysematous patients were more likely to be symptomatic, necessitating chest tube placement. Gender of the patient, site of the lesion, patient position during the procedure, and dwell time had no statistically significant relation with the frequency of post-procedural pneumothorax. Surprisingly, needle gauge had no significant effect on pneumothorax frequency, but due to the small sample size, non-randomisation, and bias in needle size selection as per lesion size, further studies are required to fully elucidate the causal relationship between needle size and post-procedural pneumothorax rate. The needle should be as perpendicular as possible to the pleura (needle-pleural angle close to 90°), to minimise the possibility of pneumothorax after percutaneous transthoracic needle biopsy.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose To assess the influence of various patient-, lesion-, and procedure-related variables on the occurrence of pneumothorax as a complication of CT-guided percutaneous transthoracic needle biopsy. Material and methods In a total of 208 patients, 215 lung/mediastinal lesions (seven patients were biopsied twice) were sampled under CT guidance using coaxial biopsy set via percutaneous transthoracic approach. Incidence of post procedure pneumothorax was seen and the influence of various patient-, lesion-, and procedure-related variables on the frequency of pneumothorax with special emphasis on procedural factors like dwell time and needle-pleural angle was analysed. Results Pneumothorax occurred in 25.12% (54/215) of patients. Increased incidence of pneumothorax had a statistically significant correlation with age of the patient (p = 0.0020), size (p = 0.0044) and depth (p = 0.0001) of the lesion, and needle-pleural angle (p = 0.0200). Gender of the patient (p = 0.7761), emphysema (p = 0.2724), site of the lesion (p = 0.9320), needle gauge (p = 0.7250), patient position (p = 0.9839), and dwell time (p = 0.9330) had no significant impact on the pneumothorax rate. Conclusions This study demonstrated a significant effect of the age of the patient, size and depth of the lesion, and needle-pleural angle on the incidence of post-procedural pneumothorax. Emphysema as such had no effect on pneumothorax rate, but once pneumothorax occurred, emphysematous patients were more likely to be symptomatic, necessitating chest tube placement. Gender of the patient, site of the lesion, patient position during the procedure, and dwell time had no statistically significant relation with the frequency of post-procedural pneumothorax. Surprisingly, needle gauge had no significant effect on pneumothorax frequency, but due to the small sample size, non-randomisation, and bias in needle size selection as per lesion size, further studies are required to fully elucidate the causal relationship between needle size and post-procedural pneumothorax rate. The needle should be as perpendicular as possible to the pleura (needle-pleural angle close to 90°), to minimise the possibility of pneumothorax after percutaneous transthoracic needle biopsy.

Key concepts: Medicine, Pneumothorax, Percutaneous, Radiology, Complication, Lesion, Percutaneous biopsy, Biopsy

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of various patient-, lesion-, and procedure-related factors on the occurrence of pneumothorax as a complication of CT-guided percutaneous transthoracic needle biopsy — Research Paper | ScholarLens