2018Journal of Applied Pharmaceutical ScienceOpen access

Validation of a simple isocratic HPLC-UV method for rifampicin and isoniazid quantification in human plasma

Laura Carolina Luciani-Giacobbe, María Laura Guzmán, Rubén H. Manzo, Marı́a Eugenia Olivera

Open full text 10 citations

Abstract

A simple and selective reversed phase HPLC-UV method for rifampicin and isoniazid quantification in human plasma was developed and validated.The method consisted of drug extraction with trichloroacetic acid and organic solvent followed by derivatization of isoniazid.Using an isocratic mode, rifampicin was analyzed on a C18 (250 × 4.6 mm, 5 µm) column at 339 nm, while isoniazid was analyzed on a C8 (250 × 4.6 mm, 5 µm) column at 273 nm.All validation parameters fulfilled the FDA requirements, as the method was accurate (bias% < 10.26), precise (CV% < 10.39) and linear from 0.31 to 37.80 μg/mL of rifampicin and 0.89 to 71.36 μg/mL of isoniazid.The samples remained stable during the usual processing and analysis times and also during the two freeze/thaw cycles.The recovery of both analytes was reproducible (CV% < 11.2) in the range of 97.3-99.6% of rifampicin and 89.8-96.6% of isoniazid.The low volume of plasma necessary for the quantification of the samples (750 µL in total) and the low limit of quantification (0.31 μg/mL for rifampicin and 0.89 μg/mL for isoniazid) made this method useful for carrying out pharmacokinetic tests both in humans or animal models.In addition, the method can be successfully applied for bioavailability studies or drug monitoring in tuberculosis treatment.

Open-access reader

About this research paper

What this paper is about

A simple and selective reversed phase HPLC-UV method for rifampicin and isoniazid quantification in human plasma was developed and validated.The method consisted of drug extraction with trichloroacetic acid and organic solvent followed by derivatization of isoniazid.Using an isocratic mode, rifampicin was analyzed on a C18 (250 × 4.6 mm, 5 µm) column at 339 nm, while isoniazid was analyzed on a C8 (250 × 4.6 mm, 5 µm) column at 273 nm.All validation parameters fulfilled the FDA requirements, as the method was accurate (bias% < 10.26), precise (CV% < 10.39) and linear from 0.31 to 37.80 μg/mL of rifampicin and 0.89 to 71.36 μg/mL of isoniazid.The samples remained stable during the usual processing and analysis times and also during the two freeze/thaw cycles.The recovery of both analytes was reproducible (CV% < 11.2) in the range of 97.3-99.6% of rifampicin and 89.8-96.6% of isoniazid.The low volume of plasma necessary for the quantification of the samples (750 µL in total) and the low limit of quantification (0.31 μg/mL for rifampicin and 0.89 μg/mL for isoniazid) made this method useful for carrying out pharmacokinetic tests both in humans or animal models.In addition, the method can be successfully applied for bioavailability studies or drug monitoring in tuberculosis treatment.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple and selective reversed phase HPLC-UV method for rifampicin and isoniazid quantification in human plasma was developed and validated.The method consisted of drug extraction with trichloroacetic acid and organic solvent followed by derivatization of isoniazid.Using an isocratic mode, rifampicin was analyzed on a C18 (250 × 4.6 mm, 5 µm) column at 339 nm, while isoniazid was analyzed on a C8 (250 × 4.6 mm, 5 µm) column at 273 nm.All validation parameters fulfilled the FDA requirements, as the method was accurate (bias% < 10.26), precise (CV% < 10.39) and linear from 0.31 to 37.80 μg/mL of rifampicin and 0.89 to 71.36 μg/mL of isoniazid.The samples remained stable during the usual processing and analysis times and also during the two freeze/thaw cycles.The recovery of both analytes was reproducible (CV% < 11.2) in the range of 97.3-99.6% of rifampicin and 89.8-96.6% of isoniazid.The low volume of plasma necessary for the quantification of the samples (750 µL in total) and the low limit of quantification (0.31 μg/mL for rifampicin and 0.89 μg/mL for isoniazid) made this method useful for carrying out pharmacokinetic tests both in humans or animal models.In addition, the method can be successfully applied for bioavailability studies or drug monitoring in tuberculosis treatment.

Key concepts: Rifampicin, Isoniazid, Vomiting, Pharmacology, Chromatography, Tuberculosis, Pharmacokinetics, Drug

Related papers

Back to paper searchBrowse research topicsOriginal source
Validation of a simple isocratic HPLC-UV method for rifampicin and isoniazid quantification in human plasma — Research Paper | ScholarLens