2019StrokeRequires access

Abstract WP261: Role of Transcranial Doppler in a New Era of Patent Foramen Ovale Closure

Edgar Olivas, Patrick D. Lyden, Shlee S Song, Oana Clementina Dumitrascu, Robert J. Jackson, Brenda Rinsky, Danielle Seth-Hunter, Michael Cavallaro, Konrad H. Schlick

Open publisher page 0 citations

Abstract

Introduction: Recent patent foramen ovale (PFO) closure trials have demonstrated efficacy in secondary stroke prevention. Transcranial Doppler (TCD) can reliably detect the presence of PFO, with sensitivity comparable to echocardiography. We sought to compare the sensitivity of TCD in detecting right to left shunt (RLS) using transesophageal echocardiogram (TEE) criteria as described in the CLOSE and REDUCE trials. Methods: We retrospectively reviewed all TCD studies at our institution who also had TEE studies. We excluded patients who had their PFO closed prior to one of these studies being performed. We classified the size of the PFO based on both REDUCE and CLOSE criteria (large was defined as greater than 25 microbubbles and greater than 30 microbubbles, respectively) and compared to the size based on the Spencer grade. Results: A total of 525 TCD bubble studies were performed at our institution from May 2013 to June 2018, 220 of which also underwent TEE. Using TEE as the gold standard, TCD detected 97.61% (41/42) of any moderate-large RLS and 100% (10/10) of any large RLS. The single patient who had a moderate RLS on TEE, but not TCD had a poor Valsalva during the TCD study. TCD detected 33 patients with RLS not detected on TEE [33% (33/100)], 33.3% of which were considered significant (Spencer grades 3-5). Conclusion: TCD is comparable to TEE in detecting moderate-to-large RLS based on REDUCE/CLOSE criteria. TCD detected an appreciable amount of RLS (a third of which were Spencer grades 3-5) not detected by TEE. Further study is needed to clarify the role of PFO closure in patients with significant RLS on TCD, but no RLS on TEE. TCD is a good alternative screening tool for RLS as compared with TEE methods from recent positive trials.

About this research paper

What this paper is about

Introduction: Recent patent foramen ovale (PFO) closure trials have demonstrated efficacy in secondary stroke prevention. Transcranial Doppler (TCD) can reliably detect the presence of PFO, with sensitivity comparable to echocardiography. We sought to compare the sensitivity of TCD in detecting right to left shunt (RLS) using transesophageal echocardiogram (TEE) criteria as described in the CLOSE and REDUCE trials. Methods: We retrospectively reviewed all TCD studies at our institution who also had TEE studies. We excluded patients who had their PFO closed prior to one of these studies being performed. We classified the size of the PFO based on both REDUCE and CLOSE criteria (large was defined as greater than 25 microbubbles and greater than 30 microbubbles, respectively) and compared to the size based on the Spencer grade. Results: A total of 525 TCD bubble studies were performed at our institution from May 2013 to June 2018, 220 of which also underwent TEE. Using TEE as the gold standard, TCD detected 97.61% (41/42) of any moderate-large RLS and 100% (10/10) of any large RLS. The single patient who had a moderate RLS on TEE, but not TCD had a poor Valsalva during the TCD study. TCD detected 33 patients with RLS not detected on TEE [33% (33/100)], 33.3% of which were considered significant (Spencer grades 3-5). Conclusion: TCD is comparable to TEE in detecting moderate-to-large RLS based on REDUCE/CLOSE criteria. TCD detected an appreciable amount of RLS (a third of which were Spencer grades 3-5) not detected by TEE. Further study is needed to clarify the role of PFO closure in patients with significant RLS on TCD, but no RLS on TEE. TCD is a good alternative screening tool for RLS as compared with TEE methods from recent positive trials.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction: Recent patent foramen ovale (PFO) closure trials have demonstrated efficacy in secondary stroke prevention. Transcranial Doppler (TCD) can reliably detect the presence of PFO, with sensitivity comparable to echocardiography. We sought to compare the sensitivity of TCD in detecting right to left shunt (RLS) using transesophageal echocardiogram (TEE) criteria as described in the CLOSE and REDUCE trials. Methods: We retrospectively reviewed all TCD studies at our institution who also had TEE studies. We excluded patients who had their PFO closed prior to one of these studies being performed. We classified the size of the PFO based on both REDUCE and CLOSE criteria (large was defined as greater than 25 microbubbles and greater than 30 microbubbles, respectively) and compared to the size based on the Spencer grade. Results: A total of 525 TCD bubble studies were performed at our institution from May 2013 to June 2018, 220 of which also underwent TEE. Using TEE as the gold standard, TCD detected 97.61% (41/42) of any moderate-large RLS and 100% (10/10) of any large RLS. The single patient who had a moderate RLS on TEE, but not TCD had a poor Valsalva during the TCD study. TCD detected 33 patients with RLS not detected on TEE [33% (33/100)], 33.3% of which were considered significant (Spencer grades 3-5). Conclusion: TCD is comparable to TEE in detecting moderate-to-large RLS based on REDUCE/CLOSE criteria. TCD detected an appreciable amount of RLS (a third of which were Spencer grades 3-5) not detected by TEE. Further study is needed to clarify the role of PFO closure in patients with significant RLS on TCD, but no RLS on TEE. TCD is a good alternative screening tool for RLS as compared with TEE methods from recent positive trials.

Key concepts: Patent foramen ovale, Medicine, Transcranial Doppler, Valsalva maneuver, Right-to-left shunt, Cardiology, Microbubbles, Stroke (engine)

Related papers

Back to paper searchBrowse research topicsOriginal source
Abstract WP261: Role of Transcranial Doppler in a New Era of Patent Foramen Ovale Closure — Research Paper | ScholarLens