2019•Journal of InstrumentationOpen access

Gamma-ray modulation properties of tungsten coded apertures for a novel mixed-field imaging system

M. Cieślak, Kelum A. A. Gamage, Robert Glover, C. James Taylor

Open full text 7 citations

Abstract

An investigation into the gamma-ray modulation properties of a tungsten coded aperture, whose design is based on the mathematical principles of Modified Uniformly Redundant Arrays (MURA), has been performed. Due to the small size of the individual cells, the aperture was built using additive manufacturing methods. The gamma-ray field was produced by a 137 Cs radioactive isotope at Lancaster University, U.K. An organic plastic scintillator sample, which is capable of pulse shape discrimination, has been used to detect the gamma-ray field modulated by a tungsten aperture. Prior to the investigation of the aperture modulation properties, energy calibration of the scintillator was performed. Its pulse shape discrimination capabilities were verified using a 252 Cf fission source. In this study, each of 169 coded aperture cells was investigated by collimating the modulated gamma-ray field of 137 Cs through a 25.4 mm thick lead supporting plate. The supporting plate has one opening in the centre, of the same dimensions as the single aperture cell, i.e. 2.5 mm × 2.5 mm. The number of pulses detected for every aperture location were recorded in an array. The array was subsequently used to create a two-dimensional image of the source, which was encoded through the coded aperture pattern. Finally, the image was decoded using deconvolution techniques to reveal the actual source location. The new results obtained in this study indicate that sufficient gamma-ray modulation properties of the aperture can be determined, despite the relatively small footprint and thickness of the coded aperture.

Open-access reader

About this research paper

What this paper is about

An investigation into the gamma-ray modulation properties of a tungsten coded aperture, whose design is based on the mathematical principles of Modified Uniformly Redundant Arrays (MURA), has been performed. Due to the small size of the individual cells, the aperture was built using additive manufacturing methods. The gamma-ray field was produced by a 137 Cs radioactive isotope at Lancaster University, U.K. An organic plastic scintillator sample, which is capable of pulse shape discrimination, has been used to detect the gamma-ray field modulated by a tungsten aperture. Prior to the investigation of the aperture modulation properties, energy calibration of the scintillator was performed. Its pulse shape discrimination capabilities were verified using a 252 Cf fission source. In this study, each of 169 coded aperture cells was investigated by collimating the modulated gamma-ray field of 137 Cs through a 25.4 mm thick lead supporting plate. The supporting plate has one opening in the centre, of the same dimensions as the single aperture cell, i.e. 2.5 mm × 2.5 mm. The number of pulses detected for every aperture location were recorded in an array. The array was subsequently used to create a two-dimensional image of the source, which was encoded through the coded aperture pattern. Finally, the image was decoded using deconvolution techniques to reveal the actual source location. The new results obtained in this study indicate that sufficient gamma-ray modulation properties of the aperture can be determined, despite the relatively small footprint and thickness of the coded aperture.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An investigation into the gamma-ray modulation properties of a tungsten coded aperture, whose design is based on the mathematical principles of Modified Uniformly Redundant Arrays (MURA), has been performed. Due to the small size of the individual cells, the aperture was built using additive manufacturing methods. The gamma-ray field was produced by a 137 Cs radioactive isotope at Lancaster University, U.K. An organic plastic scintillator sample, which is capable of pulse shape discrimination, has been used to detect the gamma-ray field modulated by a tungsten aperture. Prior to the investigation of the aperture modulation properties, energy calibration of the scintillator was performed. Its pulse shape discrimination capabilities were verified using a 252 Cf fission source. In this study, each of 169 coded aperture cells was investigated by collimating the modulated gamma-ray field of 137 Cs through a 25.4 mm thick lead supporting plate. The supporting plate has one opening in the centre, of the same dimensions as the single aperture cell, i.e. 2.5 mm × 2.5 mm. The number of pulses detected for every aperture location were recorded in an array. The array was subsequently used to create a two-dimensional image of the source, which was encoded through the coded aperture pattern. Finally, the image was decoded using deconvolution techniques to reveal the actual source location. The new results obtained in this study indicate that sufficient gamma-ray modulation properties of the aperture can be determined, despite the relatively small footprint and thickness of the coded aperture.

Key concepts: Tungsten, Modulation (music), Optics, Field (mathematics), Physics, X-ray, Materials science, Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
Gamma-ray modulation properties of tungsten coded apertures for a novel mixed-field imaging system — Research Paper | ScholarLens