2019ACS NanoRequires access

Microwave Radiation Detection with an Ultrathin Free-Standing Superconducting Niobium Nanohelix

Sören Lösch, A. Alfonsov, Oleksandr V. Dobrovolskiy, Robert Keil, Vivienne Engemaier, S. Baunack, Guodong Li, Oliver G. Schmidt, Danilo Bürger

Open publisher page 36 citations

Abstract

We present a superconducting bolometer fabricated by a rolled-up technology that allows one to combine the two-dimensionality (2D) of the superconducting layer with a helical spiral curvature. The bolometer is formed as a free-standing Nb nanohelix acting as an ultrathin transition-edge sensor (TES) and having a negligible thermal contact to the substrate. We demonstrate the functionality of the thin-film TES by examining its microwave-detection performance in comparison with a commercial cryogenic bolometer from QMC Instruments. The nanohelix has been revealed to feature a noise equivalent power (NEP) of about 2 × 10 –10 W Hz –1/2 at a microwave radiation power of 9 W m –2, which is 4 orders of magnitude smaller than the NEP of the QMC sensor at a similar radiation power. Furthermore, the forecast for the nanohelix is a 1 to 2 orders of magnitude shorter response time as compared to sensors based on commonly used 1 μm thick Si 3 N 4 membranes. The reason is the extremely low heat capacity of the 50 nm thick supporting material and the few contact points between the TES and the substrate. Our findings indicate that microwave radiation detection can be substantially improved by extending 2D superconducting structures into the 3D space.

About this research paper

What this paper is about

We present a superconducting bolometer fabricated by a rolled-up technology that allows one to combine the two-dimensionality (2D) of the superconducting layer with a helical spiral curvature. The bolometer is formed as a free-standing Nb nanohelix acting as an ultrathin transition-edge sensor (TES) and having a negligible thermal contact to the substrate. We demonstrate the functionality of the thin-film TES by examining its microwave-detection performance in comparison with a commercial cryogenic bolometer from QMC Instruments. The nanohelix has been revealed to feature a noise equivalent power (NEP) of about 2 × 10 –10 W Hz –1/2 at a microwave radiation power of 9 W m –2, which is 4 orders of magnitude smaller than the NEP of the QMC sensor at a similar radiation power. Furthermore, the forecast for the nanohelix is a 1 to 2 orders of magnitude shorter response time as compared to sensors based on commonly used 1 μm thick Si 3 N 4 membranes. The reason is the extremely low heat capacity of the 50 nm thick supporting material and the few contact points between the TES and the substrate. Our findings indicate that microwave radiation detection can be substantially improved by extending 2D superconducting structures into the 3D space.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present a superconducting bolometer fabricated by a rolled-up technology that allows one to combine the two-dimensionality (2D) of the superconducting layer with a helical spiral curvature. The bolometer is formed as a free-standing Nb nanohelix acting as an ultrathin transition-edge sensor (TES) and having a negligible thermal contact to the substrate. We demonstrate the functionality of the thin-film TES by examining its microwave-detection performance in comparison with a commercial cryogenic bolometer from QMC Instruments. The nanohelix has been revealed to feature a noise equivalent power (NEP) of about 2 × 10 –10 W Hz –1/2 at a microwave radiation power of 9 W m –2, which is 4 orders of magnitude smaller than the NEP of the QMC sensor at a similar radiation power. Furthermore, the forecast for the nanohelix is a 1 to 2 orders of magnitude shorter response time as compared to sensors based on commonly used 1 μm thick Si 3 N 4 membranes. The reason is the extremely low heat capacity of the 50 nm thick supporting material and the few contact points between the TES and the substrate. Our findings indicate that microwave radiation detection can be substantially improved by extending 2D superconducting structures into the 3D space.

Key concepts: Bolometer, Noise-equivalent power, Transition edge sensor, Microwave, Superconductivity, Materials science, Niobium, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
Microwave Radiation Detection with an Ultrathin Free-Standing Superconducting Niobium Nanohelix — Research Paper | ScholarLens