2019•Biomedical ChromatographyRequires access

Characterization and screening of metals, metalloids and biomarkers in crude oil by ICP–MS/OES, and GC–MS techniques after digestion by microwave‐induced combustion

Abdul Karim‐Talaq Mohammad, Abdullah Thamer Hameed, Mohammed Affan Alhamdany, Khaldun M. Al Azzam, Gaidaa Abd Alkareem Talk

Open publisher page 31 citations

Abstract

Abstract A method for digestion of light and medium Iraqi crude oils (Basrah and Khanaken oils) using microwave‐induced combustion (MIC) in closed vessels is described for the determination of Hg, Au, Cu, Al, Ca, Co, K, Mg, Si and Sr by inductively coupled plasma optical emission spectrometry (ICP–OES) and Mo, Ti, Mn, Li, Se−1, Rb, Ag, Ba, Pb, As, Cd, Cr, Fe, Ni, V and Zn by inductively coupled plasma mass spectrometry (ICP–MS). Upon using MIC it was possible to obtain lower limits of detection by ICP–MS and also by ICP–OES compared with those obtained by microwave‐assisted digestion. The MIC was the best choice with regard to the possibility of using dilute nitric acid as an absorbing solution, which is important to minimize the interference encountered by ICP–MS and ICP–OES.The physicochemical parameters and some contaminants of crude oil samples were analyzed to classify and assess the quality of the crude oils. This study determines the viability of the use of Fourier transform infrared spectroscopy as an alternativee to traditional petroleum geochemical methods for crude oil characterization. The infrared fingerprints agree with the results obtained from GC–MS analysis.

About this research paper

What this paper is about

Abstract A method for digestion of light and medium Iraqi crude oils (Basrah and Khanaken oils) using microwave‐induced combustion (MIC) in closed vessels is described for the determination of Hg, Au, Cu, Al, Ca, Co, K, Mg, Si and Sr by inductively coupled plasma optical emission spectrometry (ICP–OES) and Mo, Ti, Mn, Li, Se−1, Rb, Ag, Ba, Pb, As, Cd, Cr, Fe, Ni, V and Zn by inductively coupled plasma mass spectrometry (ICP–MS). Upon using MIC it was possible to obtain lower limits of detection by ICP–MS and also by ICP–OES compared with those obtained by microwave‐assisted digestion. The MIC was the best choice with regard to the possibility of using dilute nitric acid as an absorbing solution, which is important to minimize the interference encountered by ICP–MS and ICP–OES.The physicochemical parameters and some contaminants of crude oil samples were analyzed to classify and assess the quality of the crude oils. This study determines the viability of the use of Fourier transform infrared spectroscopy as an alternativee to traditional petroleum geochemical methods for crude oil characterization. The infrared fingerprints agree with the results obtained from GC–MS analysis.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract A method for digestion of light and medium Iraqi crude oils (Basrah and Khanaken oils) using microwave‐induced combustion (MIC) in closed vessels is described for the determination of Hg, Au, Cu, Al, Ca, Co, K, Mg, Si and Sr by inductively coupled plasma optical emission spectrometry (ICP–OES) and Mo, Ti, Mn, Li, Se−1, Rb, Ag, Ba, Pb, As, Cd, Cr, Fe, Ni, V and Zn by inductively coupled plasma mass spectrometry (ICP–MS). Upon using MIC it was possible to obtain lower limits of detection by ICP–MS and also by ICP–OES compared with those obtained by microwave‐assisted digestion. The MIC was the best choice with regard to the possibility of using dilute nitric acid as an absorbing solution, which is important to minimize the interference encountered by ICP–MS and ICP–OES.The physicochemical parameters and some contaminants of crude oil samples were analyzed to classify and assess the quality of the crude oils. This study determines the viability of the use of Fourier transform infrared spectroscopy as an alternativee to traditional petroleum geochemical methods for crude oil characterization. The infrared fingerprints agree with the results obtained from GC–MS analysis.

Key concepts: Chemistry, Microwave digestion, Inductively coupled plasma mass spectrometry, Inductively coupled plasma atomic emission spectroscopy, Inductively coupled plasma, Nitric acid, Detection limit, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Characterization and screening of metals, metalloids and biomarkers in crude oil by ICP–MS/OES, and GC–MS techniques after digestion by microwave‐induced combustion — Research Paper | ScholarLens