2018•Unpublished venueRequires access

A Subspace Based Method for Near Transducer Interference Suppression

Johan E. Carlson, Simon Ranefjard, Felix Trulsson

Open publisher page 2 citations

Abstract

In applications of direct-contact ultrasound, operating in pulse-echo mode, the transient resulting from the excitation of the transducer will mask any reflections from scatterers near the transducer surface. This results in a so called dead zone, preventing any defects to be detected. This is normally solved by introducing a delay line between the transducer and the specimen. There are drawbacks with this approach, and therefore we propose an alternative technique, which instead suppresses the transient from the excitation by a statistical modeling technique. This paper describes an algorithm for reduction of the dead zone and shows with experiments using both a single-element transducer and a 128 element linear array, that the transient from the transducer excitation can be suppressed sufficiently well to reveal side-drilled holes in a test block, which were previously masked.

About this research paper

What this paper is about

In applications of direct-contact ultrasound, operating in pulse-echo mode, the transient resulting from the excitation of the transducer will mask any reflections from scatterers near the transducer surface. This results in a so called dead zone, preventing any defects to be detected. This is normally solved by introducing a delay line between the transducer and the specimen. There are drawbacks with this approach, and therefore we propose an alternative technique, which instead suppresses the transient from the excitation by a statistical modeling technique. This paper describes an algorithm for reduction of the dead zone and shows with experiments using both a single-element transducer and a 128 element linear array, that the transient from the transducer excitation can be suppressed sufficiently well to reveal side-drilled holes in a test block, which were previously masked.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In applications of direct-contact ultrasound, operating in pulse-echo mode, the transient resulting from the excitation of the transducer will mask any reflections from scatterers near the transducer surface. This results in a so called dead zone, preventing any defects to be detected. This is normally solved by introducing a delay line between the transducer and the specimen. There are drawbacks with this approach, and therefore we propose an alternative technique, which instead suppresses the transient from the excitation by a statistical modeling technique. This paper describes an algorithm for reduction of the dead zone and shows with experiments using both a single-element transducer and a 128 element linear array, that the transient from the transducer excitation can be suppressed sufficiently well to reveal side-drilled holes in a test block, which were previously masked.

Key concepts: Transducer, Acoustics, Transient (computer programming), Excitation, Interference (communication), Materials science, Optics, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
A Subspace Based Method for Near Transducer Interference Suppression — Research Paper | ScholarLens