2018•Archives of Craniofacial SurgeryOpen access

New anthropometric data for preoperative planning in orbital wall fracture treatment: the use of eyelid drooping

Han Byul Lee, Soo Hyang Lee

Open full text 3 citations

Abstract

BACKGROUND: The presence of enophthalmos is an important determinant in the decision of orbital wall fracture surgery. We proposed eyelid drooping as a new anthropometric diagnostic measure and analyzed whether eyelid drooping is associated with enophthalmos. METHODS: This retrospective study was performed from January 2014 to December 2016. A total of 75 patients with blowout fractures were studied. One experimenter measured the degree of enophthalmos using a Hertel exophthalmometer at 1 week after trauma and at 3 months after surgery. The height change of the upper eyelid was measured using the marginal reflex distance (MRD) on both sides, and the degree of eyelid drooping was calculated by comparing the two lengths. We analyzed statistically the correlation between enophthalmos and eyelid drooping. RESULTS: We found a highly significant correlation between the degree of enophthalmos and the reduction rate of MRD (RRM, as an indicator of eyelid drooping) at 1 week after trauma (r = 0.845). Approximately 2.0 mm of enophthalmos was associated with a 30.8% reduction in MRD on the affected side as compared with the normal side. At 3 months after surgery, patients showed improved eyelid appearance, with a moderate association between enophthalmos and RRM. CONCLUSION: We demonstrated that the degree of enophthalmos, measured using an exophthalmometer, is associated with a change in the height of the upper eyelid. Thus, upper eyelid drooping can be used as another indicator for orbital wall fracture surgery. Compared with conventional methods, measurements of eyelid drooping are easy to perform, offering a great advantage and understanding to the patient.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The presence of enophthalmos is an important determinant in the decision of orbital wall fracture surgery. We proposed eyelid drooping as a new anthropometric diagnostic measure and analyzed whether eyelid drooping is associated with enophthalmos. METHODS: This retrospective study was performed from January 2014 to December 2016. A total of 75 patients with blowout fractures were studied. One experimenter measured the degree of enophthalmos using a Hertel exophthalmometer at 1 week after trauma and at 3 months after surgery. The height change of the upper eyelid was measured using the marginal reflex distance (MRD) on both sides, and the degree of eyelid drooping was calculated by comparing the two lengths. We analyzed statistically the correlation between enophthalmos and eyelid drooping. RESULTS: We found a highly significant correlation between the degree of enophthalmos and the reduction rate of MRD (RRM, as an indicator of eyelid drooping) at 1 week after trauma (r = 0.845). Approximately 2.0 mm of enophthalmos was associated with a 30.8% reduction in MRD on the affected side as compared with the normal side. At 3 months after surgery, patients showed improved eyelid appearance, with a moderate association between enophthalmos and RRM. CONCLUSION: We demonstrated that the degree of enophthalmos, measured using an exophthalmometer, is associated with a change in the height of the upper eyelid. Thus, upper eyelid drooping can be used as another indicator for orbital wall fracture surgery. Compared with conventional methods, measurements of eyelid drooping are easy to perform, offering a great advantage and understanding to the patient.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The presence of enophthalmos is an important determinant in the decision of orbital wall fracture surgery. We proposed eyelid drooping as a new anthropometric diagnostic measure and analyzed whether eyelid drooping is associated with enophthalmos. METHODS: This retrospective study was performed from January 2014 to December 2016. A total of 75 patients with blowout fractures were studied. One experimenter measured the degree of enophthalmos using a Hertel exophthalmometer at 1 week after trauma and at 3 months after surgery. The height change of the upper eyelid was measured using the marginal reflex distance (MRD) on both sides, and the degree of eyelid drooping was calculated by comparing the two lengths. We analyzed statistically the correlation between enophthalmos and eyelid drooping. RESULTS: We found a highly significant correlation between the degree of enophthalmos and the reduction rate of MRD (RRM, as an indicator of eyelid drooping) at 1 week after trauma (r = 0.845). Approximately 2.0 mm of enophthalmos was associated with a 30.8% reduction in MRD on the affected side as compared with the normal side. At 3 months after surgery, patients showed improved eyelid appearance, with a moderate association between enophthalmos and RRM. CONCLUSION: We demonstrated that the degree of enophthalmos, measured using an exophthalmometer, is associated with a change in the height of the upper eyelid. Thus, upper eyelid drooping can be used as another indicator for orbital wall fracture surgery. Compared with conventional methods, measurements of eyelid drooping are easy to perform, offering a great advantage and understanding to the patient.

Key concepts: Enophthalmos, Eyelid, Medicine, Orbital Fracture, Reduction (mathematics), Surgery, Diplopia, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
New anthropometric data for preoperative planning in orbital wall fracture treatment: the use of eyelid drooping — Research Paper | ScholarLens