2017•International Conference on Aerospace Sciences and Aviation TechnologyOpen access

Optimal Design of Orifice Flow Meter Using Computational Fluid Dynamics (CFD)

Haitham Osman, Khairy Elsayed, Mohamed El Telbany

Open full text 0 citations

Abstract

Orifice flow meter constitutes one of the most common differential pressure flow meters. However, high energy loss is occurred with the measurement process. The present research considers 3𝐷 steady simulation using Reynolds Averaged Navier–Stokes equations (RANS). New design of the orifice plate s carried out using the adjoint method. Optimal shape of orifice plate shows 55 % reduction of the pressure loss coefficient at a Reynolds number 𝑅𝑒=1.84 × 104. The discharge coefficient 𝐶𝑑 is increased by 39 %. Also, the effect of downstream ring is investigated. Optimize the shape of the ring has a slight effect on reducing energy consumed. However, applying adjoint method on the orifice plate with downstream ring achieves considerable effect in the pressure loss. Reduction by 34 % in pressure loss coefficient is obtained by the optimal orifice with downstream ring. Shape optimization by the adjoint method has a significant contribution in decreasing the consumed energy through the orifice meter.

Open-access reader

About this research paper

What this paper is about

Orifice flow meter constitutes one of the most common differential pressure flow meters. However, high energy loss is occurred with the measurement process. The present research considers 3𝐷 steady simulation using Reynolds Averaged Navier–Stokes equations (RANS). New design of the orifice plate s carried out using the adjoint method. Optimal shape of orifice plate shows 55 % reduction of the pressure loss coefficient at a Reynolds number 𝑅𝑒=1.84 × 104. The discharge coefficient 𝐶𝑑 is increased by 39 %. Also, the effect of downstream ring is investigated. Optimize the shape of the ring has a slight effect on reducing energy consumed. However, applying adjoint method on the orifice plate with downstream ring achieves considerable effect in the pressure loss. Reduction by 34 % in pressure loss coefficient is obtained by the optimal orifice with downstream ring. Shape optimization by the adjoint method has a significant contribution in decreasing the consumed energy through the orifice meter.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Orifice flow meter constitutes one of the most common differential pressure flow meters. However, high energy loss is occurred with the measurement process. The present research considers 3𝐷 steady simulation using Reynolds Averaged Navier–Stokes equations (RANS). New design of the orifice plate s carried out using the adjoint method. Optimal shape of orifice plate shows 55 % reduction of the pressure loss coefficient at a Reynolds number 𝑅𝑒=1.84 × 104. The discharge coefficient 𝐶𝑑 is increased by 39 %. Also, the effect of downstream ring is investigated. Optimize the shape of the ring has a slight effect on reducing energy consumed. However, applying adjoint method on the orifice plate with downstream ring achieves considerable effect in the pressure loss. Reduction by 34 % in pressure loss coefficient is obtained by the optimal orifice with downstream ring. Shape optimization by the adjoint method has a significant contribution in decreasing the consumed energy through the orifice meter.

Key concepts: Body orifice, Reynolds-averaged Navier–Stokes equations, Orifice plate, Computational fluid dynamics, Mechanics, Reynolds number, Flow coefficient, Discharge coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimal Design of Orifice Flow Meter Using Computational Fluid Dynamics (CFD) — Research Paper | ScholarLens