2018•MANUFACTURING TECHNOLOGYOpen access

Heat Transfer and Global Energy Balance in a Plate Heat Exchanger

Elena Pivarčiová, Mohammad Emal Qazizada

Open full text 6 citations

Abstract

Heat transfer evaluation in a plate heat exchanger (PHE) is one of the most common issue which is widely used in many engineering processes. The objective of this paper determine to formulate a global energy balance in a PHE and to study the heat losses, firstly focuses to study the heat transfer in countercurrent and parallel flow and to measure the temperature profile and to determine the number of transfer units (NTU) effectiveness of a plate heat exchanger. An addition to calculate the overall heat transfer coefficient using criteria equations, also focused to draw the temperature profile of the heat exchanger for both configurations countercurrent and parallel flow with temperature on the axial axis and thermocouple position on the horizontal axis. Furthermore discussed the behaior of temperature across the heat exchanger, compare the countercurrent and parallel flow arrangements, cpaing the experimental heat exchanger effectiveness with that estimated by the NTU method, the NTU effectiveness method application in the calculation of the output temperatures of a PHE. This concentric plate heat exchanger allows the study of heat transfer between hot water flowing through an internal sheets and cold water flowing in the ring area lying between the internal and external sheets, the plate heat exchanger allows measuring hot and cold water temperatures in different points of the heat exchanger.

Open-access reader

About this research paper

What this paper is about

Heat transfer evaluation in a plate heat exchanger (PHE) is one of the most common issue which is widely used in many engineering processes. The objective of this paper determine to formulate a global energy balance in a PHE and to study the heat losses, firstly focuses to study the heat transfer in countercurrent and parallel flow and to measure the temperature profile and to determine the number of transfer units (NTU) effectiveness of a plate heat exchanger. An addition to calculate the overall heat transfer coefficient using criteria equations, also focused to draw the temperature profile of the heat exchanger for both configurations countercurrent and parallel flow with temperature on the axial axis and thermocouple position on the horizontal axis. Furthermore discussed the behaior of temperature across the heat exchanger, compare the countercurrent and parallel flow arrangements, cpaing the experimental heat exchanger effectiveness with that estimated by the NTU method, the NTU effectiveness method application in the calculation of the output temperatures of a PHE. This concentric plate heat exchanger allows the study of heat transfer between hot water flowing through an internal sheets and cold water flowing in the ring area lying between the internal and external sheets, the plate heat exchanger allows measuring hot and cold water temperatures in different points of the heat exchanger.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Heat transfer evaluation in a plate heat exchanger (PHE) is one of the most common issue which is widely used in many engineering processes. The objective of this paper determine to formulate a global energy balance in a PHE and to study the heat losses, firstly focuses to study the heat transfer in countercurrent and parallel flow and to measure the temperature profile and to determine the number of transfer units (NTU) effectiveness of a plate heat exchanger. An addition to calculate the overall heat transfer coefficient using criteria equations, also focused to draw the temperature profile of the heat exchanger for both configurations countercurrent and parallel flow with temperature on the axial axis and thermocouple position on the horizontal axis. Furthermore discussed the behaior of temperature across the heat exchanger, compare the countercurrent and parallel flow arrangements, cpaing the experimental heat exchanger effectiveness with that estimated by the NTU method, the NTU effectiveness method application in the calculation of the output temperatures of a PHE. This concentric plate heat exchanger allows the study of heat transfer between hot water flowing through an internal sheets and cold water flowing in the ring area lying between the internal and external sheets, the plate heat exchanger allows measuring hot and cold water temperatures in different points of the heat exchanger.

Key concepts: Plate heat exchanger, Countercurrent exchange, Heat spreader, Plate fin heat exchanger, Concentric tube heat exchanger, NTU method, Heat transfer coefficient, Mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Heat Transfer and Global Energy Balance in a Plate Heat Exchanger — Research Paper | ScholarLens