2018Clinical and Experimental OphthalmologyRequires access

Biomechanical changes in the cornea following cataract surgery: A prospective assessment with the Corneal Visualisation Scheimpflug Technology

Henry B. Wallace, Stuti Lonie Misra, Sunny S. Li, James McKelvie

Open publisher page 22 citations

Abstract

IMPORTANCE: Intraocular pressure (IOP) is often reduced following cataract surgery. Postoperative changes in corneal stiffness are likely to be at least partly responsible for any reduction in IOP measured with applanation tonometry. BACKGROUND: To determine the effect of cataract surgery and corneal incision size on corneal biomechanics. DESIGN: Prospective randomized trial. PARTICIPANTS: One hundred prospectively enrolled patients qualifying for cataract surgery. METHODS: Participants were randomized to clear corneal incisions with a 2.20 or 2.85 mm keratome. Corneal Visualisation Scheimpflug Technology (Corvis-ST) tonometry and dynamic corneal response measurements were obtained preoperatively, and 3 mo postoperatively. Multiple regression analysis was completed using R software. MAIN OUTCOME MEASURES: Corvis-ST biomechanical parameters. RESULTS: Ninety-three eyes of 93 patients were included in the final analysis. Mean Corvis-ST biomechanically corrected IOP decreased by 3.63 mmHg postoperatively (95% confidence interval = 2.97-4.35, P ≤ 0.01), and central pachymetry increased by 6.96 μm (4.33-9.59, P ≤ 0.01). Independent of IOP and pachymetry changes, mean (±SE) corneal first applanation stiffness parameter reduced by 9.761 ± 3.729 (P = 0.01) postoperatively. First applanation velocity increased by 0.007 ± 0.002 ms, second applanation velocity increased by 0.012 ± 0.004 ms (P ≤ 0.01), the first applanation deformation amplitude increased by 0.008 ± 0.002 mm (P ≤ 0.01) and the deflection amplitude at highest concavity increased by 0.030 ± 0.069 (P ≤ 0.01). There were no significant differences between different incision size groups. CONCLUSIONS AND RELEVANCE: Corneal stiffness is reduced 3 mo following cataract surgery and is associated with falsely low IOP measurements. This finding may be important for glaucoma patients and in particular when assessing the effectivity of minimally invasive glaucoma surgery devices.

About this research paper

What this paper is about

IMPORTANCE: Intraocular pressure (IOP) is often reduced following cataract surgery. Postoperative changes in corneal stiffness are likely to be at least partly responsible for any reduction in IOP measured with applanation tonometry. BACKGROUND: To determine the effect of cataract surgery and corneal incision size on corneal biomechanics. DESIGN: Prospective randomized trial. PARTICIPANTS: One hundred prospectively enrolled patients qualifying for cataract surgery. METHODS: Participants were randomized to clear corneal incisions with a 2.20 or 2.85 mm keratome. Corneal Visualisation Scheimpflug Technology (Corvis-ST) tonometry and dynamic corneal response measurements were obtained preoperatively, and 3 mo postoperatively. Multiple regression analysis was completed using R software. MAIN OUTCOME MEASURES: Corvis-ST biomechanical parameters. RESULTS: Ninety-three eyes of 93 patients were included in the final analysis. Mean Corvis-ST biomechanically corrected IOP decreased by 3.63 mmHg postoperatively (95% confidence interval = 2.97-4.35, P ≤ 0.01), and central pachymetry increased by 6.96 μm (4.33-9.59, P ≤ 0.01). Independent of IOP and pachymetry changes, mean (±SE) corneal first applanation stiffness parameter reduced by 9.761 ± 3.729 (P = 0.01) postoperatively. First applanation velocity increased by 0.007 ± 0.002 ms, second applanation velocity increased by 0.012 ± 0.004 ms (P ≤ 0.01), the first applanation deformation amplitude increased by 0.008 ± 0.002 mm (P ≤ 0.01) and the deflection amplitude at highest concavity increased by 0.030 ± 0.069 (P ≤ 0.01). There were no significant differences between different incision size groups. CONCLUSIONS AND RELEVANCE: Corneal stiffness is reduced 3 mo following cataract surgery and is associated with falsely low IOP measurements. This finding may be important for glaucoma patients and in particular when assessing the effectivity of minimally invasive glaucoma surgery devices.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

IMPORTANCE: Intraocular pressure (IOP) is often reduced following cataract surgery. Postoperative changes in corneal stiffness are likely to be at least partly responsible for any reduction in IOP measured with applanation tonometry. BACKGROUND: To determine the effect of cataract surgery and corneal incision size on corneal biomechanics. DESIGN: Prospective randomized trial. PARTICIPANTS: One hundred prospectively enrolled patients qualifying for cataract surgery. METHODS: Participants were randomized to clear corneal incisions with a 2.20 or 2.85 mm keratome. Corneal Visualisation Scheimpflug Technology (Corvis-ST) tonometry and dynamic corneal response measurements were obtained preoperatively, and 3 mo postoperatively. Multiple regression analysis was completed using R software. MAIN OUTCOME MEASURES: Corvis-ST biomechanical parameters. RESULTS: Ninety-three eyes of 93 patients were included in the final analysis. Mean Corvis-ST biomechanically corrected IOP decreased by 3.63 mmHg postoperatively (95% confidence interval = 2.97-4.35, P ≤ 0.01), and central pachymetry increased by 6.96 μm (4.33-9.59, P ≤ 0.01). Independent of IOP and pachymetry changes, mean (±SE) corneal first applanation stiffness parameter reduced by 9.761 ± 3.729 (P = 0.01) postoperatively. First applanation velocity increased by 0.007 ± 0.002 ms, second applanation velocity increased by 0.012 ± 0.004 ms (P ≤ 0.01), the first applanation deformation amplitude increased by 0.008 ± 0.002 mm (P ≤ 0.01) and the deflection amplitude at highest concavity increased by 0.030 ± 0.069 (P ≤ 0.01). There were no significant differences between different incision size groups. CONCLUSIONS AND RELEVANCE: Corneal stiffness is reduced 3 mo following cataract surgery and is associated with falsely low IOP measurements. This finding may be important for glaucoma patients and in particular when assessing the effectivity of minimally invasive glaucoma surgery devices.

Key concepts: Scheimpflug principle, Medicine, Ophthalmology, Intraocular pressure, Cataract surgery, Applanation tonometry, Cornea, Prospective cohort study

Related papers

Back to paper searchBrowse research topicsOriginal source
Biomechanical changes in the cornea following cataract surgery: A prospective assessment with the Corneal Visualisation Scheimpflug Technology — Research Paper | ScholarLens