2018IEEE Transactions on Power ElectronicsRequires access

Reactive Power P&O Anti-Islanding Method for a Grid-Connected Inverter With Critical Load

Sungyoul Park, Minho Kwon, Sewan Choi

Open publisher page 35 citations

Abstract

A grid-connected inverter with critical loads should be able to supply a stable voltage to critical loads at the instant of a mode change as well as during clearing time while quickly detecting unintentional islanding. The indirect current control has been proposed to provide not only a stable voltage to critical loads during clearing time but also a seamless transfer of inverters at the instant of a mode change. However, the conventional islanding detection methods cannot be applied to the indirect current control based inverter since the magnitude and frequency of voltage do not vary when an islanding occurs. This paper proposes a reactive power P&O anti-islanding method for the indirect current control. The proposed islanding detection method generates a small reactive power perturbation at the output of the inverter and detects the islanding by observing reactive power mismatch during the islanding. Using the proposed method, the inverter can supply high quality power to critical loads without distorting the output current during the clearing time. The proposed anti-islanding method is validated through simulation and experimental results.

About this research paper

What this paper is about

A grid-connected inverter with critical loads should be able to supply a stable voltage to critical loads at the instant of a mode change as well as during clearing time while quickly detecting unintentional islanding. The indirect current control has been proposed to provide not only a stable voltage to critical loads during clearing time but also a seamless transfer of inverters at the instant of a mode change. However, the conventional islanding detection methods cannot be applied to the indirect current control based inverter since the magnitude and frequency of voltage do not vary when an islanding occurs. This paper proposes a reactive power P&O anti-islanding method for the indirect current control. The proposed islanding detection method generates a small reactive power perturbation at the output of the inverter and detects the islanding by observing reactive power mismatch during the islanding. Using the proposed method, the inverter can supply high quality power to critical loads without distorting the output current during the clearing time. The proposed anti-islanding method is validated through simulation and experimental results.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A grid-connected inverter with critical loads should be able to supply a stable voltage to critical loads at the instant of a mode change as well as during clearing time while quickly detecting unintentional islanding. The indirect current control has been proposed to provide not only a stable voltage to critical loads during clearing time but also a seamless transfer of inverters at the instant of a mode change. However, the conventional islanding detection methods cannot be applied to the indirect current control based inverter since the magnitude and frequency of voltage do not vary when an islanding occurs. This paper proposes a reactive power P&O anti-islanding method for the indirect current control. The proposed islanding detection method generates a small reactive power perturbation at the output of the inverter and detects the islanding by observing reactive power mismatch during the islanding. Using the proposed method, the inverter can supply high quality power to critical loads without distorting the output current during the clearing time. The proposed anti-islanding method is validated through simulation and experimental results.

Key concepts: Islanding, Inverter, Control theory (sociology), AC power, Voltage, Computer science, Power (physics), Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Reactive Power P&O Anti-Islanding Method for a Grid-Connected Inverter With Critical Load — Research Paper | ScholarLens