2018Romanian Journal of OphthalmologyOpen access

An overview of the influence and design of biomaterial of the intraocular implant of the posterior capsule opacification

Razvan Vladimir Nanu, Emil Ungureanu, Sînziana Istrate, Alexandra Diana Vrapciu, Roxana Cozubas, Laura Cârstocea, Voinea Liliana Mary, Radu Ciuluvică

Open full text 23 citations

Abstract

Posterior capsule opacification remains till nowadays one of the most hypothetical problems concerning the cataract surgery.When it comes in preventing PCO, this complication is made in multiple ways that concern, along with the surgery steps, the choice for the biomaterial of the intraocular implant lens.The concern of influence of the type of the used material (hydro-phob/ hydro-philic), of the design of the implant (1piece IOL = monobloc vs. 3 -piece IOL -multipiece) and with the design at the edge, they all have been considered in multiple studies.This article performs a synthesis of those studies and establishes conclusions regarding possible choices.

Open-access reader

About this research paper

What this paper is about

Posterior capsule opacification remains till nowadays one of the most hypothetical problems concerning the cataract surgery.When it comes in preventing PCO, this complication is made in multiple ways that concern, along with the surgery steps, the choice for the biomaterial of the intraocular implant lens.The concern of influence of the type of the used material (hydro-phob/ hydro-philic), of the design of the implant (1piece IOL = monobloc vs. 3 -piece IOL -multipiece) and with the design at the edge, they all have been considered in multiple studies.This article performs a synthesis of those studies and establishes conclusions regarding possible choices.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Posterior capsule opacification remains till nowadays one of the most hypothetical problems concerning the cataract surgery.When it comes in preventing PCO, this complication is made in multiple ways that concern, along with the surgery steps, the choice for the biomaterial of the intraocular implant lens.The concern of influence of the type of the used material (hydro-phob/ hydro-philic), of the design of the implant (1piece IOL = monobloc vs. 3 -piece IOL -multipiece) and with the design at the edge, they all have been considered in multiple studies.This article performs a synthesis of those studies and establishes conclusions regarding possible choices.

Key concepts: Posterior capsule opacification, Intraocular lens, Lens capsule, Implant, Cataract surgery, Intraocular lenses, Lens (geology), Biomaterial

Related papers

Back to paper searchBrowse research topicsOriginal source
An overview of the influence and design of biomaterial of the intraocular implant of the posterior capsule opacification — Research Paper | ScholarLens