Moderator material efficiency of neutron energy slowing down on D-T reaction neutron generator for SAMOP
Sigit Santosa, Anjar Anggraini
Abstract
Open-access reader
Sigit Santosa, Anjar Anggraini
Abstract
Open-access reader
We have studied a collimator design setup for the Subcritical Assembly for Mo-99 Production (SAMOP) at the Center for Accelerator Sciences and Technology (CAST), Nuclear Energy Agency of Indonesia (BATAN). The main purpose of the project is for providing sufficient neutrons to produce Mo-99, to be used to produce Tc-99m for nuclear medical applications. The modelling of the collimator is based on Monte Carlo simulation using MCNPX version 5 software to determine the variation of the suitable materials. The collimator consists of moderator, filter, and reflector, where we expected that the output of neutron will be thermal neutron with a sufficient neutron flux of about 10 8 neutron/cm 2 .s. The neutron source used is a D-T reaction neutron generator with a mono-energetic neutron energy of 14.1 MeV. The simulation has been conducted in nine variations, with each experiment uses five types of materials. The best result in terms of neutron flux is seem from the material combination of Al, C 25 H 52 , LiF, and PbF 2 , which produces a thermal neutron flux of 1.24 × 10 7 neutron/cm 2 .s and average energy deposition of 1.88 × 10 6 MeV/g. This research needs to be developed further for subsequent experiments to optimize the combination of materials and geometry systems to be used.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We have studied a collimator design setup for the Subcritical Assembly for Mo-99 Production (SAMOP) at the Center for Accelerator Sciences and Technology (CAST), Nuclear Energy Agency of Indonesia (BATAN). The main purpose of the project is for providing sufficient neutrons to produce Mo-99, to be used to produce Tc-99m for nuclear medical applications. The modelling of the collimator is based on Monte Carlo simulation using MCNPX version 5 software to determine the variation of the suitable materials. The collimator consists of moderator, filter, and reflector, where we expected that the output of neutron will be thermal neutron with a sufficient neutron flux of about 10 8 neutron/cm 2 .s. The neutron source used is a D-T reaction neutron generator with a mono-energetic neutron energy of 14.1 MeV. The simulation has been conducted in nine variations, with each experiment uses five types of materials. The best result in terms of neutron flux is seem from the material combination of Al, C 25 H 52 , LiF, and PbF 2 , which produces a thermal neutron flux of 1.24 × 10 7 neutron/cm 2 .s and average energy deposition of 1.88 × 10 6 MeV/g. This research needs to be developed further for subsequent experiments to optimize the combination of materials and geometry systems to be used.
Key concepts: Neutron generator, Neutron, Neutron flux, Neutron temperature, Neutron cross section, Collimator, Neutron moderator, Bonner sphere