Determination of chlorophenols from the industrial wastewater by GC/MS
Seung‐Woon Myung
Abstract
Seung‐Woon Myung
Abstract
The most common five chlorophenols (4-chloro-3-methylphenol, 2,4,5-trichlorophenol, 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol, pentachlorophenol) were determined from the industrial wastewater by GC/MS. The samples were collected from the petrochemical company, textile company and leather making company. The developed analytical method was modified by USEPA Method 3510. The samples were extracted with dichloromethane under pH 2 and pH 5-6, and determined by the GC/MS with SIM mode. There were good linearities (above ) on e ranges of the 0.1 ng/mL~10 ng/mL and 0.5 ng/mL~10 ng/mL, and the limit of detection were between 0.1 ng/mL and 0.5 ng/mL. The absolute recoveries were measured at the concentration of 1, 5, and 10 ng/mL, and the recovery was 71.6~98.9% except for PCP. The relative standard deviation (RSD) was 1.2~14.3% and it gave a good reproducibility for the assay. The bias, which shows the accuracy, was a good although it was a little high values (11.3~22.1%) at the low concentration (1 ng/mL).
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The most common five chlorophenols (4-chloro-3-methylphenol, 2,4,5-trichlorophenol, 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol, pentachlorophenol) were determined from the industrial wastewater by GC/MS. The samples were collected from the petrochemical company, textile company and leather making company. The developed analytical method was modified by USEPA Method 3510. The samples were extracted with dichloromethane under pH 2 and pH 5-6, and determined by the GC/MS with SIM mode. There were good linearities (above ) on e ranges of the 0.1 ng/mL~10 ng/mL and 0.5 ng/mL~10 ng/mL, and the limit of detection were between 0.1 ng/mL and 0.5 ng/mL. The absolute recoveries were measured at the concentration of 1, 5, and 10 ng/mL, and the recovery was 71.6~98.9% except for PCP. The relative standard deviation (RSD) was 1.2~14.3% and it gave a good reproducibility for the assay. The bias, which shows the accuracy, was a good although it was a little high values (11.3~22.1%) at the low concentration (1 ng/mL).
Key concepts: Chromatography, Pentachlorophenol, Chemistry, Detection limit, Relative standard deviation, Dichloromethane, Wastewater, Gas chromatography–mass spectrometry