2018Egyptian Journal of ChemistryOpen access

Rapid RP-HPLC Method for Simultaneous Estimation of Some Antidiabetics; Metformin, Gliclazide and Glimepiride in Tablets.

Mahmoud M. Sebaiy, Sobhy M. El-Adl, Mohamed M. Baraka, Amira A. Hassan

Open full text 14 citations

Abstract

An isocratic RP-HPLC method has been developed for rapid and simultaneous separation and estimation of three antidiabetics drugs, metformin, gliclazide and glimepiride in tablet dosage forms within 6 minutes. Separation was carried out on a Thermo Scientific® BDS Hypersil C8 column (5µm, 2.50 x 4.60 mm) using a mobile phase of MeOH : 0.025M KH2PO4 adjusted to pH 3.20 using ortho - phosphoric acid (70 : 30, v/v) at ambient temperature. The flow rate was 1 mL/min and UV detection was set at 235 nm. The retention time of metformin, gliclazide and glimepiride was noted to be 3.06, 4.33 and 6.00 minutes respectively, indicating a very short analysis time rather than other reported methods. Also, limits of detection were reported to be 0.05, 1.21 and 0.11 µg/mL for metformin, gliclazide and glimepiride, respectively, showing a high degree of the method sensitivity. The method was then validated according to ICH guidelines where it was found to be accurate, reproducible and robust. Finally, the method was compared statistically with reference methods indicating that there is no significant difference between them in respect of precision and accuracy.

Open-access reader

About this research paper

What this paper is about

An isocratic RP-HPLC method has been developed for rapid and simultaneous separation and estimation of three antidiabetics drugs, metformin, gliclazide and glimepiride in tablet dosage forms within 6 minutes. Separation was carried out on a Thermo Scientific® BDS Hypersil C8 column (5µm, 2.50 x 4.60 mm) using a mobile phase of MeOH : 0.025M KH2PO4 adjusted to pH 3.20 using ortho - phosphoric acid (70 : 30, v/v) at ambient temperature. The flow rate was 1 mL/min and UV detection was set at 235 nm. The retention time of metformin, gliclazide and glimepiride was noted to be 3.06, 4.33 and 6.00 minutes respectively, indicating a very short analysis time rather than other reported methods. Also, limits of detection were reported to be 0.05, 1.21 and 0.11 µg/mL for metformin, gliclazide and glimepiride, respectively, showing a high degree of the method sensitivity. The method was then validated according to ICH guidelines where it was found to be accurate, reproducible and robust. Finally, the method was compared statistically with reference methods indicating that there is no significant difference between them in respect of precision and accuracy.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An isocratic RP-HPLC method has been developed for rapid and simultaneous separation and estimation of three antidiabetics drugs, metformin, gliclazide and glimepiride in tablet dosage forms within 6 minutes. Separation was carried out on a Thermo Scientific® BDS Hypersil C8 column (5µm, 2.50 x 4.60 mm) using a mobile phase of MeOH : 0.025M KH2PO4 adjusted to pH 3.20 using ortho - phosphoric acid (70 : 30, v/v) at ambient temperature. The flow rate was 1 mL/min and UV detection was set at 235 nm. The retention time of metformin, gliclazide and glimepiride was noted to be 3.06, 4.33 and 6.00 minutes respectively, indicating a very short analysis time rather than other reported methods. Also, limits of detection were reported to be 0.05, 1.21 and 0.11 µg/mL for metformin, gliclazide and glimepiride, respectively, showing a high degree of the method sensitivity. The method was then validated according to ICH guidelines where it was found to be accurate, reproducible and robust. Finally, the method was compared statistically with reference methods indicating that there is no significant difference between them in respect of precision and accuracy.

Key concepts: Glimepiride, Gliclazide, Chromatography, Metformin, Dosage form, High-performance liquid chromatography, Phosphoric acid, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid RP-HPLC Method for Simultaneous Estimation of Some Antidiabetics; Metformin, Gliclazide and Glimepiride in Tablets. — Research Paper | ScholarLens