2018•Journal of Drug Delivery and TherapeuticsOpen access

COMPARISON OF RP-HPLC AND UV SPECTROPHOTOMETRIC METHODS FOR ESTIMATION OF HALOPERIDOL IN PURE AND PHARMACEUTICAL FORMULATION

AK Jain, B. K. Dubey, Deepak Kumar Basedia, Sanjay Dhakar, Manisha Ahirwar, P Jain

Open full text 10 citations

Abstract

An accurate, precise, sensitive and reproducible High-performance liquid chromatographic (HPLC) and UV spectrophotometric methods were developed and validated for the quantitative determination of haloperidol (HPD) in bulk drug and pharmaceutical formulation. Different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD) and limit of quantification (LOQ) were determined according to International Conference on Harmonization ICH Q2B guidelines. The RP-HPLC method was developed by the isocratic technique on a reversed-phase Thermo C18 (250 × 4.6 mm, 5µm) column with mobile phase consisting of Methanol: Acetonitrile (50:50v/v) at flow rate of 1.0 ml/min. The retention time for HPD was 2.238±0.3min. The UV spectrophotometric determinations were performed at 244 nm using 80% methanol as a solvent. The linearity range for HPD was 5-25 μg/ml for both HPLC and UV method. The linearity of the calibration curves for each analyte in the desired concentration range was good (r2 >0.999) by both the HPLC and UV methods. The method showed good reproducibility and recovery with percent relative standard deviation less than 2%. Moreover, the accuracy and precision obtained with HPLC co-related well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence successfully applied for determining the assay and in vitro dissolution of a marketed formulation. Keywords: HPLC, UV Spectrophotometry, Haloperidol, Pharmaceutical formulation, Method validation, Quantitative analysis

Open-access reader

About this research paper

What this paper is about

An accurate, precise, sensitive and reproducible High-performance liquid chromatographic (HPLC) and UV spectrophotometric methods were developed and validated for the quantitative determination of haloperidol (HPD) in bulk drug and pharmaceutical formulation. Different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD) and limit of quantification (LOQ) were determined according to International Conference on Harmonization ICH Q2B guidelines. The RP-HPLC method was developed by the isocratic technique on a reversed-phase Thermo C18 (250 × 4.6 mm, 5µm) column with mobile phase consisting of Methanol: Acetonitrile (50:50v/v) at flow rate of 1.0 ml/min. The retention time for HPD was 2.238±0.3min. The UV spectrophotometric determinations were performed at 244 nm using 80% methanol as a solvent. The linearity range for HPD was 5-25 μg/ml for both HPLC and UV method. The linearity of the calibration curves for each analyte in the desired concentration range was good (r2 >0.999) by both the HPLC and UV methods. The method showed good reproducibility and recovery with percent relative standard deviation less than 2%. Moreover, the accuracy and precision obtained with HPLC co-related well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence successfully applied for determining the assay and in vitro dissolution of a marketed formulation. Keywords: HPLC, UV Spectrophotometry, Haloperidol, Pharmaceutical formulation, Method validation, Quantitative analysis

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An accurate, precise, sensitive and reproducible High-performance liquid chromatographic (HPLC) and UV spectrophotometric methods were developed and validated for the quantitative determination of haloperidol (HPD) in bulk drug and pharmaceutical formulation. Different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD) and limit of quantification (LOQ) were determined according to International Conference on Harmonization ICH Q2B guidelines. The RP-HPLC method was developed by the isocratic technique on a reversed-phase Thermo C18 (250 × 4.6 mm, 5µm) column with mobile phase consisting of Methanol: Acetonitrile (50:50v/v) at flow rate of 1.0 ml/min. The retention time for HPD was 2.238±0.3min. The UV spectrophotometric determinations were performed at 244 nm using 80% methanol as a solvent. The linearity range for HPD was 5-25 μg/ml for both HPLC and UV method. The linearity of the calibration curves for each analyte in the desired concentration range was good (r2 >0.999) by both the HPLC and UV methods. The method showed good reproducibility and recovery with percent relative standard deviation less than 2%. Moreover, the accuracy and precision obtained with HPLC co-related well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence successfully applied for determining the assay and in vitro dissolution of a marketed formulation. Keywords: HPLC, UV Spectrophotometry, Haloperidol, Pharmaceutical formulation, Method validation, Quantitative analysis

Key concepts: Chromatography, High-performance liquid chromatography, Analyte, Detection limit, Calibration curve, Chemistry, Reproducibility, Linearity

Related papers

Back to paper searchBrowse research topicsOriginal source
COMPARISON OF RP-HPLC AND UV SPECTROPHOTOMETRIC METHODS FOR ESTIMATION OF HALOPERIDOL IN PURE AND PHARMACEUTICAL FORMULATION — Research Paper | ScholarLens