2018Unpublished venueRequires access

Onset and Post Buckling of Pipe-in-Pipe’s Helical Buckling Using Improved Energy Method

Lixin Gong

Open publisher page 2 citations

Abstract

The purpose of this paper is to present theoretical solutions based on an improved energy method for predicting the helical buckling (HB) behavior of pipes in vertical, inclined, and horizontal wells. The energy method has been applied to solve the pipe-in-pipe’s (PIP) helical buckling behavior since Lubinski, et al [2] in the 1950’s. However, in the preceding studies, the energy methods are not yet completely correct because the pipe’s potential energy of the distributed contact normal force induced by the helical buckling was considered to be negligible. This deficiency caused improper deductive procedures. In this paper, the energy method is improved by adding the term of the potential energy of the distributed contact normal force. With this improvement, not only can the PIP’s critical helical buckling forces be successfully derived, but it also provides a deeper insight on the PIP’s helical buckling onset, as well as the post helical buckling behavior. For inclined and horizontal wells, equations are provided to determine the critical forces required to initiate the helical buckling mode for both “long” and “short” pipes. In addition, the post buckling behavior is also described, and a new concept of helical buckling zone (HBZ) for “short” pipes is introduced based on the force-pitch plots as an area in-between the helical buckling’s onset curve and the classical Lubinski curve. Finite element ABAQUS models have also been utilized to confirm the analysis using the improved energy method. And the ABAQUS results show remarkable agreement with the theoretical solutions.

About this research paper

What this paper is about

The purpose of this paper is to present theoretical solutions based on an improved energy method for predicting the helical buckling (HB) behavior of pipes in vertical, inclined, and horizontal wells. The energy method has been applied to solve the pipe-in-pipe’s (PIP) helical buckling behavior since Lubinski, et al [2] in the 1950’s. However, in the preceding studies, the energy methods are not yet completely correct because the pipe’s potential energy of the distributed contact normal force induced by the helical buckling was considered to be negligible. This deficiency caused improper deductive procedures. In this paper, the energy method is improved by adding the term of the potential energy of the distributed contact normal force. With this improvement, not only can the PIP’s critical helical buckling forces be successfully derived, but it also provides a deeper insight on the PIP’s helical buckling onset, as well as the post helical buckling behavior. For inclined and horizontal wells, equations are provided to determine the critical forces required to initiate the helical buckling mode for both “long” and “short” pipes. In addition, the post buckling behavior is also described, and a new concept of helical buckling zone (HBZ) for “short” pipes is introduced based on the force-pitch plots as an area in-between the helical buckling’s onset curve and the classical Lubinski curve. Finite element ABAQUS models have also been utilized to confirm the analysis using the improved energy method. And the ABAQUS results show remarkable agreement with the theoretical solutions.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this paper is to present theoretical solutions based on an improved energy method for predicting the helical buckling (HB) behavior of pipes in vertical, inclined, and horizontal wells. The energy method has been applied to solve the pipe-in-pipe’s (PIP) helical buckling behavior since Lubinski, et al [2] in the 1950’s. However, in the preceding studies, the energy methods are not yet completely correct because the pipe’s potential energy of the distributed contact normal force induced by the helical buckling was considered to be negligible. This deficiency caused improper deductive procedures. In this paper, the energy method is improved by adding the term of the potential energy of the distributed contact normal force. With this improvement, not only can the PIP’s critical helical buckling forces be successfully derived, but it also provides a deeper insight on the PIP’s helical buckling onset, as well as the post helical buckling behavior. For inclined and horizontal wells, equations are provided to determine the critical forces required to initiate the helical buckling mode for both “long” and “short” pipes. In addition, the post buckling behavior is also described, and a new concept of helical buckling zone (HBZ) for “short” pipes is introduced based on the force-pitch plots as an area in-between the helical buckling’s onset curve and the classical Lubinski curve. Finite element ABAQUS models have also been utilized to confirm the analysis using the improved energy method. And the ABAQUS results show remarkable agreement with the theoretical solutions.

Key concepts: Buckling, Structural engineering, Energy method, Potential energy, Finite element method, Energy (signal processing), Mechanics, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Onset and Post Buckling of Pipe-in-Pipe’s Helical Buckling Using Improved Energy Method — Research Paper | ScholarLens