2018Analytical ChemistryOpen access

Complementary Ionization Techniques for the Analysis of Scotch Whisky by High Resolution Mass Spectrometry

William Kew, C. Logan Mackay, Ian Goodall, David J. Clarke, Dušan Uhrı́n

Open full text 32 citations

Abstract

Fourier transform mass spectrometry (FTMS) is widely used to characterize the chemical complexity of mixtures, such as natural organic matter (NOM), petroleum, and agri-food products (including Scotch whisky). Although electrospray ionization (ESI) is by far the most widely used ionization source in these studies, other ionization techniques are available and may offer complementary information. In a recent study, we found matrix free laser desorption/ionization (LDI) to be effective for the analysis of Suwannee river fulvic acid (SRFA), and to provide complementary chemical insights. In this study, LDI along with atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) were compared to ESI for the analysis of Scotch whisky. High mass accuracy (54 ppb, mean) allowed for the assignment of 86% of peaks, with 3993 unique molecular formulas identified from four representative samples analyzed. All four ionization techniques, performed in negative mode, identified thousands of formulas. Many were unique to each ionization source, while 699 formulas were common to all techniques. Ions were identified in both deprotonated and radical anion forms. Our study highlights the importance of a multi-ionization source approach; we recommend that analysis of complex mixtures, especially novel ones, should not be limited solely to ESI.

Open-access reader

About this research paper

What this paper is about

Fourier transform mass spectrometry (FTMS) is widely used to characterize the chemical complexity of mixtures, such as natural organic matter (NOM), petroleum, and agri-food products (including Scotch whisky). Although electrospray ionization (ESI) is by far the most widely used ionization source in these studies, other ionization techniques are available and may offer complementary information. In a recent study, we found matrix free laser desorption/ionization (LDI) to be effective for the analysis of Suwannee river fulvic acid (SRFA), and to provide complementary chemical insights. In this study, LDI along with atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) were compared to ESI for the analysis of Scotch whisky. High mass accuracy (54 ppb, mean) allowed for the assignment of 86% of peaks, with 3993 unique molecular formulas identified from four representative samples analyzed. All four ionization techniques, performed in negative mode, identified thousands of formulas. Many were unique to each ionization source, while 699 formulas were common to all techniques. Ions were identified in both deprotonated and radical anion forms. Our study highlights the importance of a multi-ionization source approach; we recommend that analysis of complex mixtures, especially novel ones, should not be limited solely to ESI.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fourier transform mass spectrometry (FTMS) is widely used to characterize the chemical complexity of mixtures, such as natural organic matter (NOM), petroleum, and agri-food products (including Scotch whisky). Although electrospray ionization (ESI) is by far the most widely used ionization source in these studies, other ionization techniques are available and may offer complementary information. In a recent study, we found matrix free laser desorption/ionization (LDI) to be effective for the analysis of Suwannee river fulvic acid (SRFA), and to provide complementary chemical insights. In this study, LDI along with atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) were compared to ESI for the analysis of Scotch whisky. High mass accuracy (54 ppb, mean) allowed for the assignment of 86% of peaks, with 3993 unique molecular formulas identified from four representative samples analyzed. All four ionization techniques, performed in negative mode, identified thousands of formulas. Many were unique to each ionization source, while 699 formulas were common to all techniques. Ions were identified in both deprotonated and radical anion forms. Our study highlights the importance of a multi-ionization source approach; we recommend that analysis of complex mixtures, especially novel ones, should not be limited solely to ESI.

Key concepts: Chemistry, Atmospheric-pressure chemical ionization, Mass spectrometry, Ionization, Photoionization, Ambient ionization, Chemical ionization, Ion source

Related papers

Back to paper searchBrowse research topicsOriginal source
Complementary Ionization Techniques for the Analysis of Scotch Whisky by High Resolution Mass Spectrometry — Research Paper | ScholarLens