2018European Journal of Engineering and Technology ResearchOpen access

Analysis of Thermal Comfort in an Office Space Using Two Typical Ventilation Modes.

Chinedum Vincent Okafor, Kevin Chuks Okolie, Peter Ogunoh, Udeagwu Hyginus Oguike

Open full text 2 citations

Abstract

This study carried out a comparative study to evaluate the air-conditioning performance of an office space under two typical ventilation modes (displacement and mixing ventilation system). A wall supply diffuser is located at the ceiling height for the mixing ventilation case, whereas, the supply diffuser is at the floor level for the displacement ventilation case. In both cases, the exhaust grill is located at the ceiling. From the result of the simulation, the researchers observed that the displacement ventilation system could have a higher risk of discomfort relating to vertical temperature gradient than when compared to the mixing ventilation case. More so, the simulation result indicates that the temperature distribution in an office building is a function of the type of ventilation system adopted and marginally affected by the diffuser arrangement.

About this research paper

What this paper is about

This study carried out a comparative study to evaluate the air-conditioning performance of an office space under two typical ventilation modes (displacement and mixing ventilation system). A wall supply diffuser is located at the ceiling height for the mixing ventilation case, whereas, the supply diffuser is at the floor level for the displacement ventilation case. In both cases, the exhaust grill is located at the ceiling. From the result of the simulation, the researchers observed that the displacement ventilation system could have a higher risk of discomfort relating to vertical temperature gradient than when compared to the mixing ventilation case. More so, the simulation result indicates that the temperature distribution in an office building is a function of the type of ventilation system adopted and marginally affected by the diffuser arrangement.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study carried out a comparative study to evaluate the air-conditioning performance of an office space under two typical ventilation modes (displacement and mixing ventilation system). A wall supply diffuser is located at the ceiling height for the mixing ventilation case, whereas, the supply diffuser is at the floor level for the displacement ventilation case. In both cases, the exhaust grill is located at the ceiling. From the result of the simulation, the researchers observed that the displacement ventilation system could have a higher risk of discomfort relating to vertical temperature gradient than when compared to the mixing ventilation case. More so, the simulation result indicates that the temperature distribution in an office building is a function of the type of ventilation system adopted and marginally affected by the diffuser arrangement.

Key concepts: Displacement ventilation, Ceiling (cloud), Ventilation (architecture), Diffuser (optics), Thermal comfort, Mixing (physics), Room air distribution, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of Thermal Comfort in an Office Space Using Two Typical Ventilation Modes. — Research Paper | ScholarLens