2018Journal of Clinical Laboratory AnalysisOpen access

The FLC dimer with lambda type may false‐migrate to the position of “albumin” band by urine protein electrophoresis on Sebia agarose gel‐based detection system

Changqiang Chen, Peizhan Chen, Xuqian Fang

Open full text 3 citations

Abstract

BACKGROUND: Monoclonal free light chains (FLC) commonly exist in monomeric or dimeric forms but rarely as larger molecules. Little is known about whether polymeric molecules can affect urine protein electrophoresis (UPE) results. METHODS: Urine samples were collected from 72 multiple myeloma (MM) patients with Bence Jones protein (BJP). Urine protein and immunofixation electrophoresis were analyzed on Sebia SDS "agarose" gel electrophoresis system (SDS-AGE), and immunoglobulin free light chains were measured on the BNII nephelometric assay. RESULTS: A type of disulfide-bound FLC dimer shows a pattern shift to the position of the "albumin" band in urine protein electrophoresis in multiple myeloma (MM) patients according to the Sebia agarose gel-based detection system, which was validated by immunofixation, SDS-PAGE, and mass spectrometric methods. Similar cases were found in 21 (29.17%) of 72 MM patients with BJP, and 19 (90.5%) of 21 patients were the lambda type. CONCLUSIONS: These results indicate that BJP with lambda type has a strong tendency to abnormally migrate, which may increase the risk of misinterpretation of protein electrophoresis in clinics. Thus, when the urine protein electrophoresis is inconsistent with the result by nephelometric method, urine protein electrophoresis needs to be repeated on the deduced condition to confirm the essence of the originally identified "albumin."

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Monoclonal free light chains (FLC) commonly exist in monomeric or dimeric forms but rarely as larger molecules. Little is known about whether polymeric molecules can affect urine protein electrophoresis (UPE) results. METHODS: Urine samples were collected from 72 multiple myeloma (MM) patients with Bence Jones protein (BJP). Urine protein and immunofixation electrophoresis were analyzed on Sebia SDS "agarose" gel electrophoresis system (SDS-AGE), and immunoglobulin free light chains were measured on the BNII nephelometric assay. RESULTS: A type of disulfide-bound FLC dimer shows a pattern shift to the position of the "albumin" band in urine protein electrophoresis in multiple myeloma (MM) patients according to the Sebia agarose gel-based detection system, which was validated by immunofixation, SDS-PAGE, and mass spectrometric methods. Similar cases were found in 21 (29.17%) of 72 MM patients with BJP, and 19 (90.5%) of 21 patients were the lambda type. CONCLUSIONS: These results indicate that BJP with lambda type has a strong tendency to abnormally migrate, which may increase the risk of misinterpretation of protein electrophoresis in clinics. Thus, when the urine protein electrophoresis is inconsistent with the result by nephelometric method, urine protein electrophoresis needs to be repeated on the deduced condition to confirm the essence of the originally identified "albumin."

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Monoclonal free light chains (FLC) commonly exist in monomeric or dimeric forms but rarely as larger molecules. Little is known about whether polymeric molecules can affect urine protein electrophoresis (UPE) results. METHODS: Urine samples were collected from 72 multiple myeloma (MM) patients with Bence Jones protein (BJP). Urine protein and immunofixation electrophoresis were analyzed on Sebia SDS "agarose" gel electrophoresis system (SDS-AGE), and immunoglobulin free light chains were measured on the BNII nephelometric assay. RESULTS: A type of disulfide-bound FLC dimer shows a pattern shift to the position of the "albumin" band in urine protein electrophoresis in multiple myeloma (MM) patients according to the Sebia agarose gel-based detection system, which was validated by immunofixation, SDS-PAGE, and mass spectrometric methods. Similar cases were found in 21 (29.17%) of 72 MM patients with BJP, and 19 (90.5%) of 21 patients were the lambda type. CONCLUSIONS: These results indicate that BJP with lambda type has a strong tendency to abnormally migrate, which may increase the risk of misinterpretation of protein electrophoresis in clinics. Thus, when the urine protein electrophoresis is inconsistent with the result by nephelometric method, urine protein electrophoresis needs to be repeated on the deduced condition to confirm the essence of the originally identified "albumin."

Key concepts: Bence Jones protein, Immunofixation, Gel electrophoresis of proteins, Urine, Chemistry, Serum protein electrophoresis, Agarose gel electrophoresis, Gel electrophoresis

Related papers

Back to paper searchBrowse research topicsOriginal source
The FLC dimer with lambda type may false‐migrate to the position of “albumin” band by urine protein electrophoresis on Sebia agarose gel‐based detection system — Research Paper | ScholarLens