2018Wood and Fiber ScienceOpen access

FIRE DESIGN OF CLT IN EUROPE

Birgit Östman, Joachim Schmid, Michael Klippel, Alar Just, Norman Werther, Daniël Brandon

Open full text 15 citations

Abstract

The fire safety design of cross-laminated timber (CLT or X-Lam) in Europe is governed by the Construction Products Regulation and its essential requirements, as for all other building products. These requirements are mandatory, to be used in all European countries. They include classification systems for reaction to fire of building products, fire resistance of building elements, and structural Eurocodes. The reaction-to-fire performance of CLT in accordance with the European classification system is specified. Higher classes can be reached by chemical treatments, but the durability of the reaction-to-fire performance needs to be fulfilled according to a new European system. The fire resistance design of CLT building elements is not included in Eurocode 5, the structural Eurocode for timber, but can be either tested according to European standards or calculated by using design methods being developed recently. This article provides information about both reaction to fire and fire resistance of CLT in Europe.

Open-access reader

About this research paper

What this paper is about

The fire safety design of cross-laminated timber (CLT or X-Lam) in Europe is governed by the Construction Products Regulation and its essential requirements, as for all other building products. These requirements are mandatory, to be used in all European countries. They include classification systems for reaction to fire of building products, fire resistance of building elements, and structural Eurocodes. The reaction-to-fire performance of CLT in accordance with the European classification system is specified. Higher classes can be reached by chemical treatments, but the durability of the reaction-to-fire performance needs to be fulfilled according to a new European system. The fire resistance design of CLT building elements is not included in Eurocode 5, the structural Eurocode for timber, but can be either tested according to European standards or calculated by using design methods being developed recently. This article provides information about both reaction to fire and fire resistance of CLT in Europe.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The fire safety design of cross-laminated timber (CLT or X-Lam) in Europe is governed by the Construction Products Regulation and its essential requirements, as for all other building products. These requirements are mandatory, to be used in all European countries. They include classification systems for reaction to fire of building products, fire resistance of building elements, and structural Eurocodes. The reaction-to-fire performance of CLT in accordance with the European classification system is specified. Higher classes can be reached by chemical treatments, but the durability of the reaction-to-fire performance needs to be fulfilled according to a new European system. The fire resistance design of CLT building elements is not included in Eurocode 5, the structural Eurocode for timber, but can be either tested according to European standards or calculated by using design methods being developed recently. This article provides information about both reaction to fire and fire resistance of CLT in Europe.

Key concepts: Eurocode, Cross laminated timber, Fire resistance, Durability, Engineering, Fire protection, Fire safety, Forensic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
FIRE DESIGN OF CLT IN EUROPE — Research Paper | ScholarLens