2018•Unpublished venueRequires access

Effect of Interharmonics on Flicker of Fluorescent Lamps

Huiyan Cao, Tianci Li, Yuanlin Song, Bo Zhu, Xiaolei Yang, Chengye Yuan

Open publisher page 3 citations

Abstract

In order to analyze the inter-harmonic affections on the voltage flicker, the relationship between the inter-harmonics and flicker analysis are carried out. In order to be able to accurately determine the level of inter-harmonics to make the electric light flicker, inter-harmonic-flicker limit curve drawing method based on the voltage flicker constraints is established. Analog tester flicker and inter-harmonic-flicker experimental platform are built; limit curve can be drawn through the experimental data. The 2 kinds of harmonic-flicker limit curves for the 220 V, 50 Hz fluorescent lamp are drawn by the 2 methods separately, and the analysis results show that the accuracy of the results obtained by the two methods, the level of inter-harmonics whether lead to fluorescent flicker can be determined by the curves. The methods have the small amount of calculation, and are practical and easy to implement.

About this research paper

What this paper is about

In order to analyze the inter-harmonic affections on the voltage flicker, the relationship between the inter-harmonics and flicker analysis are carried out. In order to be able to accurately determine the level of inter-harmonics to make the electric light flicker, inter-harmonic-flicker limit curve drawing method based on the voltage flicker constraints is established. Analog tester flicker and inter-harmonic-flicker experimental platform are built; limit curve can be drawn through the experimental data. The 2 kinds of harmonic-flicker limit curves for the 220 V, 50 Hz fluorescent lamp are drawn by the 2 methods separately, and the analysis results show that the accuracy of the results obtained by the two methods, the level of inter-harmonics whether lead to fluorescent flicker can be determined by the curves. The methods have the small amount of calculation, and are practical and easy to implement.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to analyze the inter-harmonic affections on the voltage flicker, the relationship between the inter-harmonics and flicker analysis are carried out. In order to be able to accurately determine the level of inter-harmonics to make the electric light flicker, inter-harmonic-flicker limit curve drawing method based on the voltage flicker constraints is established. Analog tester flicker and inter-harmonic-flicker experimental platform are built; limit curve can be drawn through the experimental data. The 2 kinds of harmonic-flicker limit curves for the 220 V, 50 Hz fluorescent lamp are drawn by the 2 methods separately, and the analysis results show that the accuracy of the results obtained by the two methods, the level of inter-harmonics whether lead to fluorescent flicker can be determined by the curves. The methods have the small amount of calculation, and are practical and easy to implement.

Key concepts: Flicker, Harmonics, Limit (mathematics), Harmonic, Harmonic analysis, Voltage, Optics, Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Interharmonics on Flicker of Fluorescent Lamps — Research Paper | ScholarLens