2010•StrokeRequires access

Maps of Time to Maximum and Time to Peak for Mismatch Definition in Clinical Stroke Studies Validated With Positron Emission Tomography

OlivierZaro-Weber, WalterMoeller-Hartmann, Wolf-DieterHeiss, JanSobesky

Open publisher page 0 citations

Abstract

Background and Purpose—Perfusion-weighted imaging-derived maps of time-to-maximum (Tmax) are increasingly used to identify the tissue at risk in clinical stroke studies (eg, DEFUSE and EPITHET). Using quantitative positron emission tomography (PET), we evaluated Tmax to define the penumbral flow threshold in stroke patients and compared its performance to nondeconvolved time-to-peak (TTP) maps. Methods—Comparative perfusion-weighted imaging and quantitative 15O-water PET images of acute stroke patients were analyzed using cortical regions of interest. A receiver-operating characteristic curve analysis described the threshold independent performance of Tmax (area under the curve) and identified the best threshold (equal sensitivity and specificity threshold) to identify penumbral flow (<20 mL/100 g/min on PET cerebral blood flow). The results were compared with nondeconvolved TTP and other current perfusion-weighted imaging maps using the Mann–Whitney rank-sum test. Results—In 26 patients (time delay betwe...

About this research paper

What this paper is about

Background and Purpose—Perfusion-weighted imaging-derived maps of time-to-maximum (Tmax) are increasingly used to identify the tissue at risk in clinical stroke studies (eg, DEFUSE and EPITHET). Using quantitative positron emission tomography (PET), we evaluated Tmax to define the penumbral flow threshold in stroke patients and compared its performance to nondeconvolved time-to-peak (TTP) maps. Methods—Comparative perfusion-weighted imaging and quantitative 15O-water PET images of acute stroke patients were analyzed using cortical regions of interest. A receiver-operating characteristic curve analysis described the threshold independent performance of Tmax (area under the curve) and identified the best threshold (equal sensitivity and specificity threshold) to identify penumbral flow (<20 mL/100 g/min on PET cerebral blood flow). The results were compared with nondeconvolved TTP and other current perfusion-weighted imaging maps using the Mann–Whitney rank-sum test. Results—In 26 patients (time delay betwe...

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background and Purpose—Perfusion-weighted imaging-derived maps of time-to-maximum (Tmax) are increasingly used to identify the tissue at risk in clinical stroke studies (eg, DEFUSE and EPITHET). Using quantitative positron emission tomography (PET), we evaluated Tmax to define the penumbral flow threshold in stroke patients and compared its performance to nondeconvolved time-to-peak (TTP) maps. Methods—Comparative perfusion-weighted imaging and quantitative 15O-water PET images of acute stroke patients were analyzed using cortical regions of interest. A receiver-operating characteristic curve analysis described the threshold independent performance of Tmax (area under the curve) and identified the best threshold (equal sensitivity and specificity threshold) to identify penumbral flow (<20 mL/100 g/min on PET cerebral blood flow). The results were compared with nondeconvolved TTP and other current perfusion-weighted imaging maps using the Mann–Whitney rank-sum test. Results—In 26 patients (time delay betwe...

Key concepts: Medicine, Positron emission tomography, Penumbra, Receiver operating characteristic, Cerebral blood flow, Nuclear medicine, Stroke (engine), Perfusion scanning

Related papers

Back to paper searchBrowse research topicsOriginal source
Maps of Time to Maximum and Time to Peak for Mismatch Definition in Clinical Stroke Studies Validated With Positron Emission Tomography — Research Paper | ScholarLens