2018•Analytical ChemistryOpen access

Dual-Laser Tetra-Polarization FRET (4polFRET) for Site-Selective Control of Homo-FRET in Hetero-FRET Systems on the Cell Surface: The Homo-FRET Gate

László Bene, Miklós Bagdány, Tamás Ungvári, László Damjanovich

Open full text 11 citations

Abstract

The effects of donor homo-Förster resonance energy transfer (homo-FRET) taking place in hetero-FRET systems is described in the context of hetero-FRET detection via donor and acceptor fluorescence anisotropies in cell surface receptor clusters. Donor homo-FRET can influence both the efficiency of detection as well as the magnitude of the detectable hetero-FRET. A 4-fold polarized FRET detection scheme—tetrapolarization FRET (4polFRET)—is proposed not only for discriminating the effects of homo-FRET from those of hetero-FRET, but also for correlating homo-associations of the donors and acceptors at different donor–acceptor distances, even beyond the critical Förster distance for hetero-FRET ( R 0 ). The method is based on suppressing homo-FRET at the donor side with red-edge excitation. After the anisotropy effects of physical rotation and homo-FRET were separated by site-selective spectroscopy, the magnitude of the effect of homo-FRET on hetero-FRET has been estimated. It has been found significant, offering a new sensitive technique for detecting conformational dynamics via the homo-FRET mediated component of hetero-FRET, the “homo-FRET enhanced hetero-FRET” or “homo-FRET gate”. The method is realizable in flow, as well as in image cytometry equipped with polarization detecting facility.

About this research paper

What this paper is about

The effects of donor homo-Förster resonance energy transfer (homo-FRET) taking place in hetero-FRET systems is described in the context of hetero-FRET detection via donor and acceptor fluorescence anisotropies in cell surface receptor clusters. Donor homo-FRET can influence both the efficiency of detection as well as the magnitude of the detectable hetero-FRET. A 4-fold polarized FRET detection scheme—tetrapolarization FRET (4polFRET)—is proposed not only for discriminating the effects of homo-FRET from those of hetero-FRET, but also for correlating homo-associations of the donors and acceptors at different donor–acceptor distances, even beyond the critical Förster distance for hetero-FRET ( R 0 ). The method is based on suppressing homo-FRET at the donor side with red-edge excitation. After the anisotropy effects of physical rotation and homo-FRET were separated by site-selective spectroscopy, the magnitude of the effect of homo-FRET on hetero-FRET has been estimated. It has been found significant, offering a new sensitive technique for detecting conformational dynamics via the homo-FRET mediated component of hetero-FRET, the “homo-FRET enhanced hetero-FRET” or “homo-FRET gate”. The method is realizable in flow, as well as in image cytometry equipped with polarization detecting facility.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effects of donor homo-Förster resonance energy transfer (homo-FRET) taking place in hetero-FRET systems is described in the context of hetero-FRET detection via donor and acceptor fluorescence anisotropies in cell surface receptor clusters. Donor homo-FRET can influence both the efficiency of detection as well as the magnitude of the detectable hetero-FRET. A 4-fold polarized FRET detection scheme—tetrapolarization FRET (4polFRET)—is proposed not only for discriminating the effects of homo-FRET from those of hetero-FRET, but also for correlating homo-associations of the donors and acceptors at different donor–acceptor distances, even beyond the critical Förster distance for hetero-FRET ( R 0 ). The method is based on suppressing homo-FRET at the donor side with red-edge excitation. After the anisotropy effects of physical rotation and homo-FRET were separated by site-selective spectroscopy, the magnitude of the effect of homo-FRET on hetero-FRET has been estimated. It has been found significant, offering a new sensitive technique for detecting conformational dynamics via the homo-FRET mediated component of hetero-FRET, the “homo-FRET enhanced hetero-FRET” or “homo-FRET gate”. The method is realizable in flow, as well as in image cytometry equipped with polarization detecting facility.

Key concepts: Förster resonance energy transfer, Chemistry, Fluorescence anisotropy, Acceptor, Fluorescence, Biophysics, Physics, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Dual-Laser Tetra-Polarization FRET (4polFRET) for Site-Selective Control of Homo-FRET in Hetero-FRET Systems on the Cell Surface: The Homo-FRET Gate — Research Paper | ScholarLens