2018•IOP Conference Series Materials Science and EngineeringOpen access

Determination of chromium cobalt nickel gallium niobium scandium and zirconium in the blast furnace slag of vanadium titanium magnetite by inductively coupled plasma atomic emission spectrometry

Yong Cheng

Open full text 3 citations

Abstract

In order to recover the precious metal elements in vanadium-titanium blast furnace slag, the analytical method that direct determination of the range from 0.001% ~ 0.300% chromium, cobalt nickel, gallium, niobium, scandium and zirconium in the blast furnace slag of vanadium titanium magnetite by inductively coupled plasma atomic emission spectrometry was established. Sample digestion reagent consists of hydrofluoric acid, hydrochloric acid, nitric acid and sulfuric acid, and their ratio, dosage and reaction control condition are all optimized, so make sure that the blast furnace slag of vanadium titanium magnetite can be quickly completely digested. At the same time, the high content of silicon dioxide can be removed by volatilization to simplify the sample solution matrix composition, and because of the titanium ion and sulfate ion complex reaction generating oxygen titanium sulfate ion so as to solve the high concentration of titanium matrix easy hydrolysis problem in low acidity medium, thus it greatly reduce the acidity of sample solution to reduce the matrix effect. That the influence of the spectral interferences and matrix effects in the high concentrations of titanium, iron, vanadium, aluminum, calcium and magnesium coexistence matrix system had been studied, then the test results are classified summary. The influence of substrate composition were eliminated by the matrix matching and synchronous background correction measures, and then the analytical lines, the background correction areas and working conditions of the spectrometer are all optimized according to the spectral interference test. The technical performance reached: calibration curve correlation coefficient of 0.998 or higher, detection limit of element is 0.0001% ~ 0.0003% and the measuring elements content in lower 0.0003% ~ 0.0009%, RSD is less than 15% when the element content in the range from 0.001% to 0.05%, the actual sample testing results are consistent with ICP-MS.

Open-access reader

About this research paper

What this paper is about

In order to recover the precious metal elements in vanadium-titanium blast furnace slag, the analytical method that direct determination of the range from 0.001% ~ 0.300% chromium, cobalt nickel, gallium, niobium, scandium and zirconium in the blast furnace slag of vanadium titanium magnetite by inductively coupled plasma atomic emission spectrometry was established. Sample digestion reagent consists of hydrofluoric acid, hydrochloric acid, nitric acid and sulfuric acid, and their ratio, dosage and reaction control condition are all optimized, so make sure that the blast furnace slag of vanadium titanium magnetite can be quickly completely digested. At the same time, the high content of silicon dioxide can be removed by volatilization to simplify the sample solution matrix composition, and because of the titanium ion and sulfate ion complex reaction generating oxygen titanium sulfate ion so as to solve the high concentration of titanium matrix easy hydrolysis problem in low acidity medium, thus it greatly reduce the acidity of sample solution to reduce the matrix effect. That the influence of the spectral interferences and matrix effects in the high concentrations of titanium, iron, vanadium, aluminum, calcium and magnesium coexistence matrix system had been studied, then the test results are classified summary. The influence of substrate composition were eliminated by the matrix matching and synchronous background correction measures, and then the analytical lines, the background correction areas and working conditions of the spectrometer are all optimized according to the spectral interference test. The technical performance reached: calibration curve correlation coefficient of 0.998 or higher, detection limit of element is 0.0001% ~ 0.0003% and the measuring elements content in lower 0.0003% ~ 0.0009%, RSD is less than 15% when the element content in the range from 0.001% to 0.05%, the actual sample testing results are consistent with ICP-MS.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to recover the precious metal elements in vanadium-titanium blast furnace slag, the analytical method that direct determination of the range from 0.001% ~ 0.300% chromium, cobalt nickel, gallium, niobium, scandium and zirconium in the blast furnace slag of vanadium titanium magnetite by inductively coupled plasma atomic emission spectrometry was established. Sample digestion reagent consists of hydrofluoric acid, hydrochloric acid, nitric acid and sulfuric acid, and their ratio, dosage and reaction control condition are all optimized, so make sure that the blast furnace slag of vanadium titanium magnetite can be quickly completely digested. At the same time, the high content of silicon dioxide can be removed by volatilization to simplify the sample solution matrix composition, and because of the titanium ion and sulfate ion complex reaction generating oxygen titanium sulfate ion so as to solve the high concentration of titanium matrix easy hydrolysis problem in low acidity medium, thus it greatly reduce the acidity of sample solution to reduce the matrix effect. That the influence of the spectral interferences and matrix effects in the high concentrations of titanium, iron, vanadium, aluminum, calcium and magnesium coexistence matrix system had been studied, then the test results are classified summary. The influence of substrate composition were eliminated by the matrix matching and synchronous background correction measures, and then the analytical lines, the background correction areas and working conditions of the spectrometer are all optimized according to the spectral interference test. The technical performance reached: calibration curve correlation coefficient of 0.998 or higher, detection limit of element is 0.0001% ~ 0.0003% and the measuring elements content in lower 0.0003% ~ 0.0009%, RSD is less than 15% when the element content in the range from 0.001% to 0.05%, the actual sample testing results are consistent with ICP-MS.

Key concepts: Vanadium, Scandium, Titanium, Inorganic chemistry, Materials science, Magnetite, Zirconium, Niobium

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of chromium cobalt nickel gallium niobium scandium and zirconium in the blast furnace slag of vanadium titanium magnetite by inductively coupled plasma atomic emission spectrometry — Research Paper | ScholarLens