1999The KSFM Journal of Fluid MachineryRequires access

Effects of Design Variation of Check Valve on the Scroll Compressor Performance

Myeong Kyun Kim, Jin Kab Lee, Hyun Jin Kim

Open publisher page 0 citations

Abstract

An analytical study has been carried out to investigate the effects of the check valve installation on the volumetric and adiabatic efficiencies in a scroll compressor. Both the valve displacement limit and the valve stiffness affected the valve motion, the pressure upstream of the valve, and the pattern of the mass flow through the valve to the discharge plenum. Nonetheless, the presence of the check valve did not cause any noticeable change in the volumetric efficiency. Only a slight increase in the compression work was needed to overcome the pressure increase in front of the valve. The pressure build-up upstream of the valve can be alleviated with the larger limit of the valve lift and a smaller valve stiffness.

About this research paper

What this paper is about

An analytical study has been carried out to investigate the effects of the check valve installation on the volumetric and adiabatic efficiencies in a scroll compressor. Both the valve displacement limit and the valve stiffness affected the valve motion, the pressure upstream of the valve, and the pattern of the mass flow through the valve to the discharge plenum. Nonetheless, the presence of the check valve did not cause any noticeable change in the volumetric efficiency. Only a slight increase in the compression work was needed to overcome the pressure increase in front of the valve. The pressure build-up upstream of the valve can be alleviated with the larger limit of the valve lift and a smaller valve stiffness.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analytical study has been carried out to investigate the effects of the check valve installation on the volumetric and adiabatic efficiencies in a scroll compressor. Both the valve displacement limit and the valve stiffness affected the valve motion, the pressure upstream of the valve, and the pattern of the mass flow through the valve to the discharge plenum. Nonetheless, the presence of the check valve did not cause any noticeable change in the volumetric efficiency. Only a slight increase in the compression work was needed to overcome the pressure increase in front of the valve. The pressure build-up upstream of the valve can be alleviated with the larger limit of the valve lift and a smaller valve stiffness.

Key concepts: Butterfly valve, Check valve, Globe valve, Valve timing, Gas compressor, Ball valve, Body orifice, Positive displacement meter