2016Environmental Engineering and Management JournalOpen access

EFFECT OF WATER FLOW RATE ON COOLING EFFECTIVENESS AND AIR TEMPERATURE CHANGE IN EVAPORATIVE COOLING PAD SYSTEMS

Cengiz Karaca, Yılmaz Yildiz, Metin Dağtekin, Zekai Gümüş

Open full text 10 citations

Abstract

In this study, it was aimed to determine the relationship between the temperature decrease of the air passing through the pad and flow rate of pad wetting water for pad evaporative cooling.In the experiments, a commercially available cellulose based evaporative cooling pad (CELdek ® 7060-15 pad) was used.Experiments were conducted at three different water flow rates (2 L min -1 m -2 ; 4 L min -1 m -2 and 6 L min -1 m -2 ) and two different air velocities (1.0 m sec -1 and 1.5 m sec -1 ).The temperature decrease of the air passing through the pad and cooling effectiveness values were lowest at water flow rate of 6 L min -1 m -2 while they were close to each other at 4 L min -1 m -2 and 2 L min -1 m -2 water flow rates.The relationship between water flow rate and the temperature decrease of the air passing through the pad was found to be statistically insignificant, while the relationship between water flow rate and cooling effectiveness was statistically significant (P<0.01).It was concluded that it is impossible to build a mathematical model between water flow rates and temperature decrease of the air passing through the pad.However, the most appropriate water flow rate for the experimental conditions was considered 4 L min -1 m -2 .

About this research paper

What this paper is about

In this study, it was aimed to determine the relationship between the temperature decrease of the air passing through the pad and flow rate of pad wetting water for pad evaporative cooling.In the experiments, a commercially available cellulose based evaporative cooling pad (CELdek ® 7060-15 pad) was used.Experiments were conducted at three different water flow rates (2 L min -1 m -2 ; 4 L min -1 m -2 and 6 L min -1 m -2 ) and two different air velocities (1.0 m sec -1 and 1.5 m sec -1 ).The temperature decrease of the air passing through the pad and cooling effectiveness values were lowest at water flow rate of 6 L min -1 m -2 while they were close to each other at 4 L min -1 m -2 and 2 L min -1 m -2 water flow rates.The relationship between water flow rate and the temperature decrease of the air passing through the pad was found to be statistically insignificant, while the relationship between water flow rate and cooling effectiveness was statistically significant (P<0.01).It was concluded that it is impossible to build a mathematical model between water flow rates and temperature decrease of the air passing through the pad.However, the most appropriate water flow rate for the experimental conditions was considered 4 L min -1 m -2 .

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, it was aimed to determine the relationship between the temperature decrease of the air passing through the pad and flow rate of pad wetting water for pad evaporative cooling.In the experiments, a commercially available cellulose based evaporative cooling pad (CELdek ® 7060-15 pad) was used.Experiments were conducted at three different water flow rates (2 L min -1 m -2 ; 4 L min -1 m -2 and 6 L min -1 m -2 ) and two different air velocities (1.0 m sec -1 and 1.5 m sec -1 ).The temperature decrease of the air passing through the pad and cooling effectiveness values were lowest at water flow rate of 6 L min -1 m -2 while they were close to each other at 4 L min -1 m -2 and 2 L min -1 m -2 water flow rates.The relationship between water flow rate and the temperature decrease of the air passing through the pad was found to be statistically insignificant, while the relationship between water flow rate and cooling effectiveness was statistically significant (P<0.01).It was concluded that it is impossible to build a mathematical model between water flow rates and temperature decrease of the air passing through the pad.However, the most appropriate water flow rate for the experimental conditions was considered 4 L min -1 m -2 .

Key concepts: Evaporative cooler, Water cooling, Environmental science, Volumetric flow rate, Materials science, Flow (mathematics), Mechanics, Process engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
EFFECT OF WATER FLOW RATE ON COOLING EFFECTIVENESS AND AIR TEMPERATURE CHANGE IN EVAPORATIVE COOLING PAD SYSTEMS — Research Paper | ScholarLens