2018ElectrophoresisOpen access

Dispersive liquid–liquid microextraction of five chlorophenols in water samples followed by determination using capillary electrophoresis

Fangfang Gao, Wenhui Lü, Huitao Liu, Jinhua Li, Lingxin Chen

Open full text 17 citations

Abstract

Dispersive liquid-liquid microextraction (DLLME) coupled with CE was developed for simultaneous determination of five types of chlorophenols (CPs), namely 2-chlorophenol (2-CP), 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP), 2,6-dichlorophenol (2,6-DCP), and 2,4,6-trichlorophenol (2,4,6-TCP) in water samples. Several parameters affecting DLLME and CE conditions were systematically investigated. Under the optimized DLLME-CE conditions, the five CPs were separated completely within 7.5 min and good enrichment factors were obtained of 40, 193, 102, 15, and 107 for 4-CP, 2,4,6-TCP, 2,4-DCP, 2-CP, and 2,6-DCP, respectively. Good linearity was attained in the range of 1-200 μg/L for 2,4,6-TCP, 2,4-DCP, 2-300 μg/L for 4-CP and 2-CP, and 1-300 μg/L for 2,6-DCP, with correlation coefficients (r) over 0.99. The LOD (S/N = 3) and the LOQ (S/N = 10) were 0.31-0.75 μg/L and 1.01-2.43 μg/L, respectively. Recoveries ranging from 60.85 to 112.36% were obtained with tap, lake, and river water spiked at three concentration levels and the RSDs (for n = 3) were 1.31-11.38%. With the characteristics of simplicity, cost-saving, and environmental friendliness, the developed DLLME-CE method proved to be potentially applicable for the rapid, sensitive, and simultaneous determination of trace CPs in complicated water samples.

Open-access reader

About this research paper

What this paper is about

Dispersive liquid-liquid microextraction (DLLME) coupled with CE was developed for simultaneous determination of five types of chlorophenols (CPs), namely 2-chlorophenol (2-CP), 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP), 2,6-dichlorophenol (2,6-DCP), and 2,4,6-trichlorophenol (2,4,6-TCP) in water samples. Several parameters affecting DLLME and CE conditions were systematically investigated. Under the optimized DLLME-CE conditions, the five CPs were separated completely within 7.5 min and good enrichment factors were obtained of 40, 193, 102, 15, and 107 for 4-CP, 2,4,6-TCP, 2,4-DCP, 2-CP, and 2,6-DCP, respectively. Good linearity was attained in the range of 1-200 μg/L for 2,4,6-TCP, 2,4-DCP, 2-300 μg/L for 4-CP and 2-CP, and 1-300 μg/L for 2,6-DCP, with correlation coefficients (r) over 0.99. The LOD (S/N = 3) and the LOQ (S/N = 10) were 0.31-0.75 μg/L and 1.01-2.43 μg/L, respectively. Recoveries ranging from 60.85 to 112.36% were obtained with tap, lake, and river water spiked at three concentration levels and the RSDs (for n = 3) were 1.31-11.38%. With the characteristics of simplicity, cost-saving, and environmental friendliness, the developed DLLME-CE method proved to be potentially applicable for the rapid, sensitive, and simultaneous determination of trace CPs in complicated water samples.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Dispersive liquid-liquid microextraction (DLLME) coupled with CE was developed for simultaneous determination of five types of chlorophenols (CPs), namely 2-chlorophenol (2-CP), 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP), 2,6-dichlorophenol (2,6-DCP), and 2,4,6-trichlorophenol (2,4,6-TCP) in water samples. Several parameters affecting DLLME and CE conditions were systematically investigated. Under the optimized DLLME-CE conditions, the five CPs were separated completely within 7.5 min and good enrichment factors were obtained of 40, 193, 102, 15, and 107 for 4-CP, 2,4,6-TCP, 2,4-DCP, 2-CP, and 2,6-DCP, respectively. Good linearity was attained in the range of 1-200 μg/L for 2,4,6-TCP, 2,4-DCP, 2-300 μg/L for 4-CP and 2-CP, and 1-300 μg/L for 2,6-DCP, with correlation coefficients (r) over 0.99. The LOD (S/N = 3) and the LOQ (S/N = 10) were 0.31-0.75 μg/L and 1.01-2.43 μg/L, respectively. Recoveries ranging from 60.85 to 112.36% were obtained with tap, lake, and river water spiked at three concentration levels and the RSDs (for n = 3) were 1.31-11.38%. With the characteristics of simplicity, cost-saving, and environmental friendliness, the developed DLLME-CE method proved to be potentially applicable for the rapid, sensitive, and simultaneous determination of trace CPs in complicated water samples.

Key concepts: Capillary electrophoresis, Chromatography, Liquid liquid, Chemistry, Capillary action, Solid-phase microextraction, Analytical Chemistry (journal), Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Dispersive liquid–liquid microextraction of five chlorophenols in water samples followed by determination using capillary electrophoresis — Research Paper | ScholarLens