BACKGROUND: Numerous short stemmed total hip arthroplasty (THA) implants have been introduced over the last decades. It is questionable if little differences between the implant designs affect stress shielding and bone remodeling. The finite element analysis allows an evaluation of the design rationale of the implant without negative side effects for the patient.OBJECTIVE: We investigated a relatively new short stemmed implant designed from clustered CT datasets of proximal femurs. How does the implant affect femoral bone remodeling? Can we see a positive effect on bone remodeling from the CT based design? METHODS: We used a Finite Element Model that was validated by a prospective dual-energy-x-ray-absorptiometry study to calculate apparent bone density.RESULTS: Apparent bone density (ABD) decreased by 2.3% in the entire femur. Bone mass loss was pronounced in the proximal calcar region. Little ABD increase was seen in the lateral aspect of the cortical ring, in the minor trochanter area and at the lateral aspect of the stem. CONCLUSIONS: ABD reduction occurs in the proximal regions of the femur. The overall bone mass loss was little after THA with the investigated implant. The specific design seems to have no major effect on stress shielding or load distribution.

About this research paper

What this paper is about

BACKGROUND: Numerous short stemmed total hip arthroplasty (THA) implants have been introduced over the last decades. It is questionable if little differences between the implant designs affect stress shielding and bone remodeling. The finite element analysis allows an evaluation of the design rationale of the implant without negative side effects for the patient.OBJECTIVE: We investigated a relatively new short stemmed implant designed from clustered CT datasets of proximal femurs. How does the implant affect femoral bone remodeling? Can we see a positive effect on bone remodeling from the CT based design? METHODS: We used a Finite Element Model that was validated by a prospective dual-energy-x-ray-absorptiometry study to calculate apparent bone density.RESULTS: Apparent bone density (ABD) decreased by 2.3% in the entire femur. Bone mass loss was pronounced in the proximal calcar region. Little ABD increase was seen in the lateral aspect of the cortical ring, in the minor trochanter area and at the lateral aspect of the stem. CONCLUSIONS: ABD reduction occurs in the proximal regions of the femur. The overall bone mass loss was little after THA with the investigated implant. The specific design seems to have no major effect on stress shielding or load distribution.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Numerous short stemmed total hip arthroplasty (THA) implants have been introduced over the last decades. It is questionable if little differences between the implant designs affect stress shielding and bone remodeling. The finite element analysis allows an evaluation of the design rationale of the implant without negative side effects for the patient.OBJECTIVE: We investigated a relatively new short stemmed implant designed from clustered CT datasets of proximal femurs. How does the implant affect femoral bone remodeling? Can we see a positive effect on bone remodeling from the CT based design? METHODS: We used a Finite Element Model that was validated by a prospective dual-energy-x-ray-absorptiometry study to calculate apparent bone density.RESULTS: Apparent bone density (ABD) decreased by 2.3% in the entire femur. Bone mass loss was pronounced in the proximal calcar region. Little ABD increase was seen in the lateral aspect of the cortical ring, in the minor trochanter area and at the lateral aspect of the stem. CONCLUSIONS: ABD reduction occurs in the proximal regions of the femur. The overall bone mass loss was little after THA with the investigated implant. The specific design seems to have no major effect on stress shielding or load distribution.

Key concepts: Stress shielding, Calcar, Implant, Femur, Trochanter, Bone remodeling, Bone density, Reduction (mathematics)