2011Guoji yiyao weisheng daobaoRequires access

Determination of levofloxacin in plasma by HPLC and its pharmacokinetics study

WU Wei-Pei, Wenming Tan, Chu Xiao-xiang, Ding Li

Open publisher page 0 citations

Abstract

Objective To develop an HPLC-UV assay for the determination of levofloxacin in human plasma, and evaluate the pharmacokinetics and bioequivalence. Methods After being deproteined by perchloric acid (20%, v/v), samples were separated by HPLC on a reversed-phase C18 column with a mobile phase of water-acetonitrile- triethylamine-acetic acid (81∶19∶0.5∶1, V/V/V/V)and with the flow rate 1.0 ml · min-1. A randomized crossover design was performed in 20 healthy volunteers. In the two study periods, a single dose of two tablets was administered to each volunteer. Results The calibration curve was linear among the range 0.05 ~ 5 μg·ml-1 T1/2. Tmax and Cmax were (6.46 ± 0.77) h, (0.9 ± 0.3) h and ( 2.74 ± 0.75 ) ug/L for the test tablet and (6.58 ± 1) h, (1.0 ± 0.59) h and (2.55 ± 0.54)ug/L for the reference tablet, re spectively. The relative bioavailability of the test tablet was(105.55 ± 12.30)%. The results of variance analysis and two one-sided t-test showed that there was no significant difference between the two preparations in the AUC and Cmax. Conclusion The assay was proved to be sensitive,accurate and convenient. The two preparations were bioequivalent. Key words: levofloxacin;  pharmacokinetics;  HPLC

About this research paper

What this paper is about

Objective To develop an HPLC-UV assay for the determination of levofloxacin in human plasma, and evaluate the pharmacokinetics and bioequivalence. Methods After being deproteined by perchloric acid (20%, v/v), samples were separated by HPLC on a reversed-phase C18 column with a mobile phase of water-acetonitrile- triethylamine-acetic acid (81∶19∶0.5∶1, V/V/V/V)and with the flow rate 1.0 ml · min-1. A randomized crossover design was performed in 20 healthy volunteers. In the two study periods, a single dose of two tablets was administered to each volunteer. Results The calibration curve was linear among the range 0.05 ~ 5 μg·ml-1 T1/2. Tmax and Cmax were (6.46 ± 0.77) h, (0.9 ± 0.3) h and ( 2.74 ± 0.75 ) ug/L for the test tablet and (6.58 ± 1) h, (1.0 ± 0.59) h and (2.55 ± 0.54)ug/L for the reference tablet, re spectively. The relative bioavailability of the test tablet was(105.55 ± 12.30)%. The results of variance analysis and two one-sided t-test showed that there was no significant difference between the two preparations in the AUC and Cmax. Conclusion The assay was proved to be sensitive,accurate and convenient. The two preparations were bioequivalent. Key words: levofloxacin;  pharmacokinetics;  HPLC

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop an HPLC-UV assay for the determination of levofloxacin in human plasma, and evaluate the pharmacokinetics and bioequivalence. Methods After being deproteined by perchloric acid (20%, v/v), samples were separated by HPLC on a reversed-phase C18 column with a mobile phase of water-acetonitrile- triethylamine-acetic acid (81∶19∶0.5∶1, V/V/V/V)and with the flow rate 1.0 ml · min-1. A randomized crossover design was performed in 20 healthy volunteers. In the two study periods, a single dose of two tablets was administered to each volunteer. Results The calibration curve was linear among the range 0.05 ~ 5 μg·ml-1 T1/2. Tmax and Cmax were (6.46 ± 0.77) h, (0.9 ± 0.3) h and ( 2.74 ± 0.75 ) ug/L for the test tablet and (6.58 ± 1) h, (1.0 ± 0.59) h and (2.55 ± 0.54)ug/L for the reference tablet, re spectively. The relative bioavailability of the test tablet was(105.55 ± 12.30)%. The results of variance analysis and two one-sided t-test showed that there was no significant difference between the two preparations in the AUC and Cmax. Conclusion The assay was proved to be sensitive,accurate and convenient. The two preparations were bioequivalent. Key words: levofloxacin;  pharmacokinetics;  HPLC

Key concepts: Bioequivalence, Pharmacokinetics, High-performance liquid chromatography, Chromatography, Levofloxacin, Bioavailability, Cmax, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of levofloxacin in plasma by HPLC and its pharmacokinetics study — Research Paper | ScholarLens