Effect of Thermo-Mechanical Aging on The Marginal Fit of Two Types of Monolithic Zirconia Crowns With Two Finish Line Designs
Khaled mohamed Haggag, Muhammad Abbas, Hussein Ramadan
Abstract
Open-access reader
Khaled mohamed Haggag, Muhammad Abbas, Hussein Ramadan
Abstract
Open-access reader
OBJECTIVES: The purpose of this study was to compare the marginal fit of two CAD/CAM monolithic zirconia crowns with two finish line designs after thermo-mechanical aging. MATERIALS AND METHODS: A total of 20 zirconia crowns were divided into two groups Bruxzir and Prettau zirconia (n=10). Each type of zirconiacrowns was divided into two groups according to the finish line design chisel (CH) and deep chamfer (DC) groups (n=5) After cementation of crowns to their correspondingdies, the vertical marginal gap was measured then the all crowns of both groups were subjected to thermo-mechanical aging then the vertical marginal gap was measured again. RESULTS: Statistical analysis showed that. The thermo-mechanical aging significantly increased the vertical marginal gap where DC non-aged Bruxzir recording the lowest mean value (31.41±5.9) and the CH aged Bruxzir recorded the highest mean value (95.28±9.2) as indicated by three-way ANOVA test (F= 23.0741,p=<0.0001<0.05). CONCLUSIONS: Thermo-mechanical aging significantly increasedthe vertical Marginal gap and the deep chamfer finish line preparation is preferredfor construction of monolithic zirconia crowns.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVES: The purpose of this study was to compare the marginal fit of two CAD/CAM monolithic zirconia crowns with two finish line designs after thermo-mechanical aging. MATERIALS AND METHODS: A total of 20 zirconia crowns were divided into two groups Bruxzir and Prettau zirconia (n=10). Each type of zirconiacrowns was divided into two groups according to the finish line design chisel (CH) and deep chamfer (DC) groups (n=5) After cementation of crowns to their correspondingdies, the vertical marginal gap was measured then the all crowns of both groups were subjected to thermo-mechanical aging then the vertical marginal gap was measured again. RESULTS: Statistical analysis showed that. The thermo-mechanical aging significantly increased the vertical marginal gap where DC non-aged Bruxzir recording the lowest mean value (31.41±5.9) and the CH aged Bruxzir recorded the highest mean value (95.28±9.2) as indicated by three-way ANOVA test (F= 23.0741,p=<0.0001<0.05). CONCLUSIONS: Thermo-mechanical aging significantly increasedthe vertical Marginal gap and the deep chamfer finish line preparation is preferredfor construction of monolithic zirconia crowns.
Key concepts: Chamfer (geometry), Finish line, Cubic zirconia, Materials science, Cementation (geology), Composite material, Orthodontics, Mathematics