2017UMP Institutional Repository (Universiti Malaysia Pahang)Open access

Kinetic study for Ultrasonic assisted Membrane Anaerobic System (UMAS) treating decanter Palm Oil Mill Effluent (POME)

U. Q. A Mansor, Asmida Ismail, Asdarina Yahya, Nur Fathin Amirah Shafie, Ayub Md Som, Abdurahman Hamid Nour, Rosli Mohd Yunus

Open full text 1 citations

Abstract

The discharge of Palm Oil Mill Effluent (POME) to river or sewage causes serious environmental problem and the use of Ultrasonic-assisted Membrane Anaerobic System (UMAS) is recommended as a solution. However, further use of UMAS in treating POME tends to give blockage on the membrane surface. Monod Model kinetic parameters of control, reacted and permeate samples of POME which contribute to membrane fouling were investigated. In this study, the treatment was operated in 5 hours at which three hours treatment was with ultrasonic application. The results show that the permeate sample has the lowest maximum specific growth rate, µmax which indicates the higher amount of biomass in UMAS reactor. The amount of biomass in UMAS was increased by using ultrasonic application which prevents the membrane from fouling problem. Therefore, it is recommended to employ UMAS in POME treatments.

Open-access reader

About this research paper

What this paper is about

The discharge of Palm Oil Mill Effluent (POME) to river or sewage causes serious environmental problem and the use of Ultrasonic-assisted Membrane Anaerobic System (UMAS) is recommended as a solution. However, further use of UMAS in treating POME tends to give blockage on the membrane surface. Monod Model kinetic parameters of control, reacted and permeate samples of POME which contribute to membrane fouling were investigated. In this study, the treatment was operated in 5 hours at which three hours treatment was with ultrasonic application. The results show that the permeate sample has the lowest maximum specific growth rate, µmax which indicates the higher amount of biomass in UMAS reactor. The amount of biomass in UMAS was increased by using ultrasonic application which prevents the membrane from fouling problem. Therefore, it is recommended to employ UMAS in POME treatments.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The discharge of Palm Oil Mill Effluent (POME) to river or sewage causes serious environmental problem and the use of Ultrasonic-assisted Membrane Anaerobic System (UMAS) is recommended as a solution. However, further use of UMAS in treating POME tends to give blockage on the membrane surface. Monod Model kinetic parameters of control, reacted and permeate samples of POME which contribute to membrane fouling were investigated. In this study, the treatment was operated in 5 hours at which three hours treatment was with ultrasonic application. The results show that the permeate sample has the lowest maximum specific growth rate, µmax which indicates the higher amount of biomass in UMAS reactor. The amount of biomass in UMAS was increased by using ultrasonic application which prevents the membrane from fouling problem. Therefore, it is recommended to employ UMAS in POME treatments.

Key concepts: Pome, Pulp and paper industry, Membrane fouling, Membrane, Fouling, Waste management, Effluent, Sewage treatment