2018Clinical ophthalmologyOpen access

Transitional conic toric intraocular lens for the management of corneal astigmatism in cataract surgery

Francisco Bandeira, Mercè Morral, Daniel Elíes, Sergio Eguiza, Spyridoula Souki, Felicidad Manero, José L. Güell

Open full text 10 citations

Abstract

SYNOPSIS: Transitional toric intraocular lens (IOL) was developed to improve refractive outcomes in cataract surgery. We report refractive, vectorial outcomes, and stability of spherical equivalent over 12 months after implantation of this IOL. PURPOSE: ) for the correction of corneal astigmatism in patients undergoing cataract surgery. SETTING: The Ocular Microsurgery Institute (IMO), a private practice in Barcelona, Spain. DESIGN: This is a retrospective, non-randomized study. METHODS: Retrospective chart review of 156 patients with preoperative regular corneal astigmatism >0.75 diopters (D) who underwent consecutive phacoemulsification and Precizon toric IOL implantation between January 2014 and December 2015 was performed. Two groups were divided according to attempted residual refraction: group 1 with emmetropia and group 2 with mild myopia for monovision. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and manifest refraction were analyzed preoperatively and 3, 6, and 12 months postoperatively. RESULTS: Precizon toric IOL was implanted in 97 eyes of 61 patients. Six months postoperatively, none of the eyes lost any line of CDVA. In all, 98% of the eyes were within ±1.00 D of attempted spherical correction. The mean preoperative keratometric cylinder was 1.92 ± 1.04 D (range 0.75-6.78), and the mean postoperative refractive cylinder was 0.77 ± 0.50 D (range 0-2.25), with 81% of the eyes with ≤1.00 D of residual cylinder. Two IOLs required realignment due to intra-operative positioning error. Eleven eyes required enhancement with corneal refractive surgery. CONCLUSION: Preexisting regular corneal astigmatism was effectively and safely corrected by the implantation of the transitional conic toric IOL in patients undergoing cataract surgery.

Open-access reader

About this research paper

What this paper is about

SYNOPSIS: Transitional toric intraocular lens (IOL) was developed to improve refractive outcomes in cataract surgery. We report refractive, vectorial outcomes, and stability of spherical equivalent over 12 months after implantation of this IOL. PURPOSE: ) for the correction of corneal astigmatism in patients undergoing cataract surgery. SETTING: The Ocular Microsurgery Institute (IMO), a private practice in Barcelona, Spain. DESIGN: This is a retrospective, non-randomized study. METHODS: Retrospective chart review of 156 patients with preoperative regular corneal astigmatism >0.75 diopters (D) who underwent consecutive phacoemulsification and Precizon toric IOL implantation between January 2014 and December 2015 was performed. Two groups were divided according to attempted residual refraction: group 1 with emmetropia and group 2 with mild myopia for monovision. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and manifest refraction were analyzed preoperatively and 3, 6, and 12 months postoperatively. RESULTS: Precizon toric IOL was implanted in 97 eyes of 61 patients. Six months postoperatively, none of the eyes lost any line of CDVA. In all, 98% of the eyes were within ±1.00 D of attempted spherical correction. The mean preoperative keratometric cylinder was 1.92 ± 1.04 D (range 0.75-6.78), and the mean postoperative refractive cylinder was 0.77 ± 0.50 D (range 0-2.25), with 81% of the eyes with ≤1.00 D of residual cylinder. Two IOLs required realignment due to intra-operative positioning error. Eleven eyes required enhancement with corneal refractive surgery. CONCLUSION: Preexisting regular corneal astigmatism was effectively and safely corrected by the implantation of the transitional conic toric IOL in patients undergoing cataract surgery.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

SYNOPSIS: Transitional toric intraocular lens (IOL) was developed to improve refractive outcomes in cataract surgery. We report refractive, vectorial outcomes, and stability of spherical equivalent over 12 months after implantation of this IOL. PURPOSE: ) for the correction of corneal astigmatism in patients undergoing cataract surgery. SETTING: The Ocular Microsurgery Institute (IMO), a private practice in Barcelona, Spain. DESIGN: This is a retrospective, non-randomized study. METHODS: Retrospective chart review of 156 patients with preoperative regular corneal astigmatism >0.75 diopters (D) who underwent consecutive phacoemulsification and Precizon toric IOL implantation between January 2014 and December 2015 was performed. Two groups were divided according to attempted residual refraction: group 1 with emmetropia and group 2 with mild myopia for monovision. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and manifest refraction were analyzed preoperatively and 3, 6, and 12 months postoperatively. RESULTS: Precizon toric IOL was implanted in 97 eyes of 61 patients. Six months postoperatively, none of the eyes lost any line of CDVA. In all, 98% of the eyes were within ±1.00 D of attempted spherical correction. The mean preoperative keratometric cylinder was 1.92 ± 1.04 D (range 0.75-6.78), and the mean postoperative refractive cylinder was 0.77 ± 0.50 D (range 0-2.25), with 81% of the eyes with ≤1.00 D of residual cylinder. Two IOLs required realignment due to intra-operative positioning error. Eleven eyes required enhancement with corneal refractive surgery. CONCLUSION: Preexisting regular corneal astigmatism was effectively and safely corrected by the implantation of the transitional conic toric IOL in patients undergoing cataract surgery.

Key concepts: Medicine, Ophthalmology, Intraocular lens, Cataract surgery, Astigmatism, Optometry, Optics, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Transitional conic toric intraocular lens for the management of corneal astigmatism in cataract surgery — Research Paper | ScholarLens