2018•MedicineOpen access

The effect of low-dose rocuronium on rapid tracheal intubation using a video laryngoscope

Sung-Mi Ji, Jeong-Gug Lee, Seok Kon Kim, Hyungseok Seo, Bong-Jae Lee

Open full text 3 citations

Abstract

BACKGROUND: The aim of this study was to investigate the clinical effectiveness of rocuronium in low doses on conditions during rapid tracheal intubation using video laryngoscope. METHODS: Ninety-eight patients undergoing otolaryngologic surgery were randomly divided into 2 groups: group L using 0.3 mg/kg of rocuronium intravenously (n = 49) and group C using 0.6 mg/kg of rocuronium (n = 49). Sixty seconds after rocuronium administration, tracheal intubation was performed using a video laryngoscope. The overall intubation condition was evaluated along with specific conditions, including laryngoscopy condition, vocal cord position, and intubation response. Intubation profiles, including Cormack-Lehane grade, 1st attempt success rate, and intubation time, were also evaluated. RESULTS: Overall intubation conditions showed a significant difference between group L and group C (P = .003). Although the incidence of vigorous response after tracheal intubation was higher in group L than in group C (P = .022), laryngoscopy condition and vocal cord position were similar between the 2 groups (P = .145 and .070, respectively). Intubation profiles showed no differences between the 2 groups. The frequency and amount of additional rocuronium administration during surgery were also similar. CONCLUSIONS: Low-dose rocuronium provided significantly worse overall intubation conditions compared to the conventional dose of rocuronium for rapid tracheal intubation. However, when using a video laryngoscope, it may provide clinically acceptable laryngeal muscle relaxation.

About this research paper

What this paper is about

BACKGROUND: The aim of this study was to investigate the clinical effectiveness of rocuronium in low doses on conditions during rapid tracheal intubation using video laryngoscope. METHODS: Ninety-eight patients undergoing otolaryngologic surgery were randomly divided into 2 groups: group L using 0.3 mg/kg of rocuronium intravenously (n = 49) and group C using 0.6 mg/kg of rocuronium (n = 49). Sixty seconds after rocuronium administration, tracheal intubation was performed using a video laryngoscope. The overall intubation condition was evaluated along with specific conditions, including laryngoscopy condition, vocal cord position, and intubation response. Intubation profiles, including Cormack-Lehane grade, 1st attempt success rate, and intubation time, were also evaluated. RESULTS: Overall intubation conditions showed a significant difference between group L and group C (P = .003). Although the incidence of vigorous response after tracheal intubation was higher in group L than in group C (P = .022), laryngoscopy condition and vocal cord position were similar between the 2 groups (P = .145 and .070, respectively). Intubation profiles showed no differences between the 2 groups. The frequency and amount of additional rocuronium administration during surgery were also similar. CONCLUSIONS: Low-dose rocuronium provided significantly worse overall intubation conditions compared to the conventional dose of rocuronium for rapid tracheal intubation. However, when using a video laryngoscope, it may provide clinically acceptable laryngeal muscle relaxation.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The aim of this study was to investigate the clinical effectiveness of rocuronium in low doses on conditions during rapid tracheal intubation using video laryngoscope. METHODS: Ninety-eight patients undergoing otolaryngologic surgery were randomly divided into 2 groups: group L using 0.3 mg/kg of rocuronium intravenously (n = 49) and group C using 0.6 mg/kg of rocuronium (n = 49). Sixty seconds after rocuronium administration, tracheal intubation was performed using a video laryngoscope. The overall intubation condition was evaluated along with specific conditions, including laryngoscopy condition, vocal cord position, and intubation response. Intubation profiles, including Cormack-Lehane grade, 1st attempt success rate, and intubation time, were also evaluated. RESULTS: Overall intubation conditions showed a significant difference between group L and group C (P = .003). Although the incidence of vigorous response after tracheal intubation was higher in group L than in group C (P = .022), laryngoscopy condition and vocal cord position were similar between the 2 groups (P = .145 and .070, respectively). Intubation profiles showed no differences between the 2 groups. The frequency and amount of additional rocuronium administration during surgery were also similar. CONCLUSIONS: Low-dose rocuronium provided significantly worse overall intubation conditions compared to the conventional dose of rocuronium for rapid tracheal intubation. However, when using a video laryngoscope, it may provide clinically acceptable laryngeal muscle relaxation.

Key concepts: Rocuronium, Medicine, Intubation, Laryngoscopy, Tracheal intubation, Anesthesia, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of low-dose rocuronium on rapid tracheal intubation using a video laryngoscope — Research Paper | ScholarLens