2018SensorsOpen access

Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure

J. Höer, Oliver Wetter

Open full text 11 citations

Abstract

BACKGROUND: Failure of laparotomy closure develops after up to 20% of abdominal operations. Suture tension has an influence on the quality of tissue regeneration. No sensors are available to register suture tension dynamics in vivo. METHODS: In a series of animal experiments, the effect of suture tension on the ultrastructure of the healing incision was examined. Surgeons' ability to suture with target tension was tested. An implantable sensor and data logger were developed and tested experimentally in sutures closing midline laparotomies in pigs both under normal and elevated intra-abdominal pressure. RESULTS: High suture tension has a negative influence on the regeneration of laparotomy incisions. Running sutures for laparotomy closure lose 45% of their initial tension over periods of 23 h. Intermittent elevation of intra-abdominal pressure to 30 mm Hg leads to a near total loss of suture tension after 23 h. CONCLUSION: Surgeons are not able to control and reproduce suture tension. Suture tension dynamics can be measured in vivo by the sensor developed. Further research is needed to define a tissue-specific suture tension optimum to reduce the incidence of complications after laparotomy. Techniques for laparotomy closure need to be modified.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Failure of laparotomy closure develops after up to 20% of abdominal operations. Suture tension has an influence on the quality of tissue regeneration. No sensors are available to register suture tension dynamics in vivo. METHODS: In a series of animal experiments, the effect of suture tension on the ultrastructure of the healing incision was examined. Surgeons' ability to suture with target tension was tested. An implantable sensor and data logger were developed and tested experimentally in sutures closing midline laparotomies in pigs both under normal and elevated intra-abdominal pressure. RESULTS: High suture tension has a negative influence on the regeneration of laparotomy incisions. Running sutures for laparotomy closure lose 45% of their initial tension over periods of 23 h. Intermittent elevation of intra-abdominal pressure to 30 mm Hg leads to a near total loss of suture tension after 23 h. CONCLUSION: Surgeons are not able to control and reproduce suture tension. Suture tension dynamics can be measured in vivo by the sensor developed. Further research is needed to define a tissue-specific suture tension optimum to reduce the incidence of complications after laparotomy. Techniques for laparotomy closure need to be modified.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Failure of laparotomy closure develops after up to 20% of abdominal operations. Suture tension has an influence on the quality of tissue regeneration. No sensors are available to register suture tension dynamics in vivo. METHODS: In a series of animal experiments, the effect of suture tension on the ultrastructure of the healing incision was examined. Surgeons' ability to suture with target tension was tested. An implantable sensor and data logger were developed and tested experimentally in sutures closing midline laparotomies in pigs both under normal and elevated intra-abdominal pressure. RESULTS: High suture tension has a negative influence on the regeneration of laparotomy incisions. Running sutures for laparotomy closure lose 45% of their initial tension over periods of 23 h. Intermittent elevation of intra-abdominal pressure to 30 mm Hg leads to a near total loss of suture tension after 23 h. CONCLUSION: Surgeons are not able to control and reproduce suture tension. Suture tension dynamics can be measured in vivo by the sensor developed. Further research is needed to define a tissue-specific suture tension optimum to reduce the incidence of complications after laparotomy. Techniques for laparotomy closure need to be modified.

Key concepts: Laparotomy, Fibrous joint, Tension (geology), Surgery, Medicine, In vivo, Biomedical engineering, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure — Research Paper | ScholarLens