Determination of Flicker Contribution Level by Using Proposed Index
Murat Silsüpür, Belgin Emre Türkay
Abstract
Open-access reader
Murat Silsüpür, Belgin Emre Türkay
Abstract
Open-access reader
Depending on different load characteristics, various power quality disturbances such as sag-swell, harmonics, inter-harmonics, and flicker, appear in electric power systems. Among these power quality disturbances, the flicker is one of the critical power quality phenomenon due to the lack of source detection and disturbance responsibility sharing method. The measurement of the flicker level is defined in the IEC 61000-4-15 standard by a flicker meter. This meter deals only with voltage signals and is not sufficient to understand the contribution of the load and background power systems separately. Thus, this paper proposes new approaches to the evaluation of flicker characteristics using the real on-site measurements taken from two different iron and steel factories. The novelty of this paper is investigating the flicker characteristics in light of statistical methods, spectral and multi-resolution wavelet analysis, and the information theory based wavelet energy entropy analysis together, and proposing a new index to interpret the flicker responsibility of load and power system. This proposed index is called Flicker Contribution Ratio (FCR) and represents the percentage flicker disturbance responsibility of both load and power system.DOI: http://dx.doi.org/10.5755/j01.eie.24.2.20631
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Depending on different load characteristics, various power quality disturbances such as sag-swell, harmonics, inter-harmonics, and flicker, appear in electric power systems. Among these power quality disturbances, the flicker is one of the critical power quality phenomenon due to the lack of source detection and disturbance responsibility sharing method. The measurement of the flicker level is defined in the IEC 61000-4-15 standard by a flicker meter. This meter deals only with voltage signals and is not sufficient to understand the contribution of the load and background power systems separately. Thus, this paper proposes new approaches to the evaluation of flicker characteristics using the real on-site measurements taken from two different iron and steel factories. The novelty of this paper is investigating the flicker characteristics in light of statistical methods, spectral and multi-resolution wavelet analysis, and the information theory based wavelet energy entropy analysis together, and proposing a new index to interpret the flicker responsibility of load and power system. This proposed index is called Flicker Contribution Ratio (FCR) and represents the percentage flicker disturbance responsibility of both load and power system.DOI: http://dx.doi.org/10.5755/j01.eie.24.2.20631
Key concepts: Flicker, Harmonics, Electric power quality, Power quality, Electric power system, Wavelet, Control theory (sociology), Electronic engineering