A Validation Study of the Impression Replica Technique
Sofia Segerström, Johanna Wiking-Lima de Faria, Michael Braian, Arman Ameri, Camilla Ahlgren
Abstract
Sofia Segerström, Johanna Wiking-Lima de Faria, Michael Braian, Arman Ameri, Camilla Ahlgren
Abstract
PURPOSE: To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. MATERIALS AND METHODS: The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. RESULTS: The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. CONCLUSION: The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry.
OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. MATERIALS AND METHODS: The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. RESULTS: The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. CONCLUSION: The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry.
Key concepts: Replica, Impression, Computer science, Range (aeronautics), Orthodontics, Materials science, Dentistry, Biomedical engineering