The Barrow Biomimetic Spine: Comparative Testing of a 3D-Printed L4-L5 Schwab Grade 2 Osteotomy Model to a Cadaveric Model

Michael A. Bohl, Michael A. Mooney, Garrett J. Repp, Claudio Cavallo, Peter Nakaji, Steve W. Chang, Jay D. Turner, Udaya Kumar Kakarla

Open full text 17 citations

Abstract

Introduction The Barrow Biomimetic Spine project is an ongoing effort to develop a three-dimensional (3D)-printed synthetic spine model with high anatomical and biomechanical fidelity to human tissue. The purpose of this study was to evaluate the biomechanical performance of an L4-L5 3D-printed synthetic spine model in a lordotic correction test after Schwab grade 2 osteotomies as compared to human cadaveric spines that have undergone the same osteotomies and lordotic correction. Methods Ten different L4-L5 synthetic spine models were 3D printed. Each print varied in either the material used for the soft tissue components, the infill density of the bony and soft tissue structures, the pre-correction disc height, or the model orientation on the print bed. Each print was instrumented with pedicle screws and underwent a Schwab grade 2 osteotomy. Changes in disc height measurements and end-plate angle were compared against cadaveric data acquired using the same study method. Results A simple linear correlation analysis demonstrated that for horizontally printed models using PolyFlex (Polymaker, New York, NY, USA)(models 1-3, 8, 10), the pre-correction posterior disc height and lordotic correction were moderately correlated (r = 0.56), but this correlation did not achieve statistical significance (P = 0.12). Regression analysis demonstrated a very strong correlation between lordotic correction and change in posterior disc height (r = 0.92, P < 0.001). Models printed either vertically (models 4-6) or with low bone density and high soft tissue density (model 10) appeared to perform the most similarly to the cadaveric tissue. Discussion The 3D-printed synthetic spine models demonstrated predictable and reliable performance in a lordotic correction test based on their respective material qualities and print densities. The print variables tested further demonstrated that this model is capable of achieving high biomechanical fidelity to cadaveric tissue when subjected to the same lordotic correction test after Schwab grade 2 osteotomies.

Open-access reader

About this research paper

What this paper is about

Introduction The Barrow Biomimetic Spine project is an ongoing effort to develop a three-dimensional (3D)-printed synthetic spine model with high anatomical and biomechanical fidelity to human tissue. The purpose of this study was to evaluate the biomechanical performance of an L4-L5 3D-printed synthetic spine model in a lordotic correction test after Schwab grade 2 osteotomies as compared to human cadaveric spines that have undergone the same osteotomies and lordotic correction. Methods Ten different L4-L5 synthetic spine models were 3D printed. Each print varied in either the material used for the soft tissue components, the infill density of the bony and soft tissue structures, the pre-correction disc height, or the model orientation on the print bed. Each print was instrumented with pedicle screws and underwent a Schwab grade 2 osteotomy. Changes in disc height measurements and end-plate angle were compared against cadaveric data acquired using the same study method. Results A simple linear correlation analysis demonstrated that for horizontally printed models using PolyFlex (Polymaker, New York, NY, USA)(models 1-3, 8, 10), the pre-correction posterior disc height and lordotic correction were moderately correlated (r = 0.56), but this correlation did not achieve statistical significance (P = 0.12). Regression analysis demonstrated a very strong correlation between lordotic correction and change in posterior disc height (r = 0.92, P < 0.001). Models printed either vertically (models 4-6) or with low bone density and high soft tissue density (model 10) appeared to perform the most similarly to the cadaveric tissue. Discussion The 3D-printed synthetic spine models demonstrated predictable and reliable performance in a lordotic correction test based on their respective material qualities and print densities. The print variables tested further demonstrated that this model is capable of achieving high biomechanical fidelity to cadaveric tissue when subjected to the same lordotic correction test after Schwab grade 2 osteotomies.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction The Barrow Biomimetic Spine project is an ongoing effort to develop a three-dimensional (3D)-printed synthetic spine model with high anatomical and biomechanical fidelity to human tissue. The purpose of this study was to evaluate the biomechanical performance of an L4-L5 3D-printed synthetic spine model in a lordotic correction test after Schwab grade 2 osteotomies as compared to human cadaveric spines that have undergone the same osteotomies and lordotic correction. Methods Ten different L4-L5 synthetic spine models were 3D printed. Each print varied in either the material used for the soft tissue components, the infill density of the bony and soft tissue structures, the pre-correction disc height, or the model orientation on the print bed. Each print was instrumented with pedicle screws and underwent a Schwab grade 2 osteotomy. Changes in disc height measurements and end-plate angle were compared against cadaveric data acquired using the same study method. Results A simple linear correlation analysis demonstrated that for horizontally printed models using PolyFlex (Polymaker, New York, NY, USA)(models 1-3, 8, 10), the pre-correction posterior disc height and lordotic correction were moderately correlated (r = 0.56), but this correlation did not achieve statistical significance (P = 0.12). Regression analysis demonstrated a very strong correlation between lordotic correction and change in posterior disc height (r = 0.92, P < 0.001). Models printed either vertically (models 4-6) or with low bone density and high soft tissue density (model 10) appeared to perform the most similarly to the cadaveric tissue. Discussion The 3D-printed synthetic spine models demonstrated predictable and reliable performance in a lordotic correction test based on their respective material qualities and print densities. The print variables tested further demonstrated that this model is capable of achieving high biomechanical fidelity to cadaveric tissue when subjected to the same lordotic correction test after Schwab grade 2 osteotomies.

Key concepts: Cadaveric spasm, 3d printed, Medicine, Soft tissue, Osteotomy, Orthodontics, Cadaver, SPINE (molecular biology)

Related papers

Back to paper searchBrowse research topicsOriginal source
The Barrow Biomimetic Spine: Comparative Testing of a 3D-Printed L4-L5 Schwab Grade 2 Osteotomy Model to a Cadaveric Model — Research Paper | ScholarLens