2018•International Journal of Laboratory HematologyRequires access

Congenital dysfibrinogenaemia assessed by whole blood thromboelastography

Aiqiu Wei, Lin Liao, Li Xiang, Jie Yan, Wenjun Yang, Gisele Alborghetti Nai, Minqi Luo, Donghong Deng, Faquan Lin

Open publisher page 12 citations

Abstract

INTRODUCTION: Congenital dysfibrinogenaemia (CD) is a rare hereditary blood disorder, and thromboelastography (TEG) can comprehensively assess the clotting function of patients. However, only few studies have focussed on the application of TEG in CD. We aim to investigate the clinical value of TEG in congenital CD. METHODS: We performed TEG and routine coagulation tests, including plasma prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), functional fibrinogen (Fg) concentration (Clauss method) and Fg concentration (PT-derived method) tests, in 17 patients with CD (experimental group) and 28 healthy individuals (control group). RESULTS: In the TEG test, the coagulation time was significantly longer and the angle value was significantly smaller in the experimental group than that in the control group (3.73 ± 1.73 minutes vs 1.99 ± 0.49 minutes; 52.39°±11.6° vs 65.69°±4.43°; P < .05 for both); the coagulation index was significantly decreased in the experimental group when compared to the control group (-0.86 ± 2.85 vs 1.29 ± 1.53) (P < .05), but the maximum amplitude was not significantly different (P > .05). In the coagulation test, compared with the control group, TT was significantly longer (11.59 ± 0.93 minutes vs 32.34 ± 7.1 minutes; P < .05) and the functional Fg concentration was significantly lower (3.17 ± 0.59 g/L vs 0.56 ± 0.18 g/L; P < .05) in the experimental group, whereas there were no differences in APTT, PT and Fg concentrations (P > .05). CONCLUSION: TEG is highly accurate for detecting coagulation function in patients with CD, with the thromboelastographic coagulation time and angle reflecting a reduced Fg activity, thereby facilitating diagnosis and differential diagnosis of CD and coagulation status evaluation of patients with CD.

About this research paper

What this paper is about

INTRODUCTION: Congenital dysfibrinogenaemia (CD) is a rare hereditary blood disorder, and thromboelastography (TEG) can comprehensively assess the clotting function of patients. However, only few studies have focussed on the application of TEG in CD. We aim to investigate the clinical value of TEG in congenital CD. METHODS: We performed TEG and routine coagulation tests, including plasma prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), functional fibrinogen (Fg) concentration (Clauss method) and Fg concentration (PT-derived method) tests, in 17 patients with CD (experimental group) and 28 healthy individuals (control group). RESULTS: In the TEG test, the coagulation time was significantly longer and the angle value was significantly smaller in the experimental group than that in the control group (3.73 ± 1.73 minutes vs 1.99 ± 0.49 minutes; 52.39°±11.6° vs 65.69°±4.43°; P < .05 for both); the coagulation index was significantly decreased in the experimental group when compared to the control group (-0.86 ± 2.85 vs 1.29 ± 1.53) (P < .05), but the maximum amplitude was not significantly different (P > .05). In the coagulation test, compared with the control group, TT was significantly longer (11.59 ± 0.93 minutes vs 32.34 ± 7.1 minutes; P < .05) and the functional Fg concentration was significantly lower (3.17 ± 0.59 g/L vs 0.56 ± 0.18 g/L; P < .05) in the experimental group, whereas there were no differences in APTT, PT and Fg concentrations (P > .05). CONCLUSION: TEG is highly accurate for detecting coagulation function in patients with CD, with the thromboelastographic coagulation time and angle reflecting a reduced Fg activity, thereby facilitating diagnosis and differential diagnosis of CD and coagulation status evaluation of patients with CD.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: Congenital dysfibrinogenaemia (CD) is a rare hereditary blood disorder, and thromboelastography (TEG) can comprehensively assess the clotting function of patients. However, only few studies have focussed on the application of TEG in CD. We aim to investigate the clinical value of TEG in congenital CD. METHODS: We performed TEG and routine coagulation tests, including plasma prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), functional fibrinogen (Fg) concentration (Clauss method) and Fg concentration (PT-derived method) tests, in 17 patients with CD (experimental group) and 28 healthy individuals (control group). RESULTS: In the TEG test, the coagulation time was significantly longer and the angle value was significantly smaller in the experimental group than that in the control group (3.73 ± 1.73 minutes vs 1.99 ± 0.49 minutes; 52.39°±11.6° vs 65.69°±4.43°; P < .05 for both); the coagulation index was significantly decreased in the experimental group when compared to the control group (-0.86 ± 2.85 vs 1.29 ± 1.53) (P < .05), but the maximum amplitude was not significantly different (P > .05). In the coagulation test, compared with the control group, TT was significantly longer (11.59 ± 0.93 minutes vs 32.34 ± 7.1 minutes; P < .05) and the functional Fg concentration was significantly lower (3.17 ± 0.59 g/L vs 0.56 ± 0.18 g/L; P < .05) in the experimental group, whereas there were no differences in APTT, PT and Fg concentrations (P > .05). CONCLUSION: TEG is highly accurate for detecting coagulation function in patients with CD, with the thromboelastographic coagulation time and angle reflecting a reduced Fg activity, thereby facilitating diagnosis and differential diagnosis of CD and coagulation status evaluation of patients with CD.

Key concepts: Thromboelastography, Partial thromboplastin time, Prothrombin time, Coagulation, Medicine, Fibrinogen, Thrombin time, Coagulation testing

Related papers

Back to paper searchBrowse research topicsOriginal source
Congenital dysfibrinogenaemia assessed by whole blood thromboelastography — Research Paper | ScholarLens