1975•Unpublished venueOpen access

Two phase pressure drop across abrupt area changes in oscillatory flow

Ohio (USA) Cincinnati Univ., J Weisman, T Ake, R Knott

Open full text 1 citations

Abstract

The ability of one-dimensional momentum balances to predict behavior during two-phase oscillatory flow has been examined. Flow oscillations in a Freon-Freon vapor system were induced by cycling a three-way valve so as to divert a varying portion of the total flow from the test section. The data taken included the phase shift between pressure and flow curves and the head fluctuation to flow fluctuation ratio. These data were compared to theoretical predictions. For void fractions below about 0.55, reasonable agreement between predictions and observations was obtained. At the highest void fractions examined, agreement between prediction and measurement was poor. However, at these high void fractions measurement errors may have been very substantial. Further, the simplifying assumptions required by the numerical calculation procedure chosen could no longer be considered valid. No real conclusion could therefore be drawn from the data at high voids. (auth)

Open-access reader

About this research paper

What this paper is about

The ability of one-dimensional momentum balances to predict behavior during two-phase oscillatory flow has been examined. Flow oscillations in a Freon-Freon vapor system were induced by cycling a three-way valve so as to divert a varying portion of the total flow from the test section. The data taken included the phase shift between pressure and flow curves and the head fluctuation to flow fluctuation ratio. These data were compared to theoretical predictions. For void fractions below about 0.55, reasonable agreement between predictions and observations was obtained. At the highest void fractions examined, agreement between prediction and measurement was poor. However, at these high void fractions measurement errors may have been very substantial. Further, the simplifying assumptions required by the numerical calculation procedure chosen could no longer be considered valid. No real conclusion could therefore be drawn from the data at high voids. (auth)

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The ability of one-dimensional momentum balances to predict behavior during two-phase oscillatory flow has been examined. Flow oscillations in a Freon-Freon vapor system were induced by cycling a three-way valve so as to divert a varying portion of the total flow from the test section. The data taken included the phase shift between pressure and flow curves and the head fluctuation to flow fluctuation ratio. These data were compared to theoretical predictions. For void fractions below about 0.55, reasonable agreement between predictions and observations was obtained. At the highest void fractions examined, agreement between prediction and measurement was poor. However, at these high void fractions measurement errors may have been very substantial. Further, the simplifying assumptions required by the numerical calculation procedure chosen could no longer be considered valid. No real conclusion could therefore be drawn from the data at high voids. (auth)

Key concepts: Freon, Mechanics, Pressure drop, Two-phase flow, Void (composites), Flow (mathematics), Thermodynamics, Porosity

Related papers

Back to paper searchBrowse research topicsOriginal source
Two phase pressure drop across abrupt area changes in oscillatory flow — Research Paper | ScholarLens