2018Journal of Applied BioanalysisOpen access

Development and Validation of a Bioanalytical Method for the Simultaneous Determination of 14 Antiretroviral Drugs using Liquid Chromatography-Tandem Mass Spectrometry

Alper Daspakan, Kai van Hateren, Ymkje Stienstra, Jos G. W. Kosterink, Tjip S. van der Werf, Daan J. Touw, Jan‐Willem C. Alffenaar

Open full text 6 citations

Abstract

OBJECTIVES: The aim was to develop and validate a LC-MS/MS assay to determine antiretrovirals in human plasma for routine therapeutic drug mon-itoring. METHODS: The selectivity, sensitivity, linearity, accuracy, precision, recovery, matrix effect, stability and dilution integrity and carry-over were validated ac-cording to EMA and FDA standards. RESULTS: For accuracy and precision, the highest overall bias was 11.3% at LLOQ of both lopinavir and saquinavir. The highest overall CV was 15.6% at the LLOQ of darunavir. Storage stability at 4°C, 20–25°C and 10°C had a maximum CV of 13.2% at low QC level (0.2 mg/L) for saquinavir. Freeze-thaw stability had a maximum overall bias of 7.4% at low QC level (0.8 mg/L) for tipranavir. Selectivity and specificity showed no interfering peaks of more than 20% of the LLOQ. CONCLUSIONS: The bioanalytical method is suitable for both TDM in stan-dard care and clinical studies. Werf T, Touw D, Alffenaar JW. Develop-ment and validation of a bioanalytical method for the simultaneous determi-nation of 14 antiretroviral drugs using liquid chromatography-tandem mass spectrometry. J Appl Bioanal 4(2), 37-50 (2018).

About this research paper

What this paper is about

OBJECTIVES: The aim was to develop and validate a LC-MS/MS assay to determine antiretrovirals in human plasma for routine therapeutic drug mon-itoring. METHODS: The selectivity, sensitivity, linearity, accuracy, precision, recovery, matrix effect, stability and dilution integrity and carry-over were validated ac-cording to EMA and FDA standards. RESULTS: For accuracy and precision, the highest overall bias was 11.3% at LLOQ of both lopinavir and saquinavir. The highest overall CV was 15.6% at the LLOQ of darunavir. Storage stability at 4°C, 20–25°C and 10°C had a maximum CV of 13.2% at low QC level (0.2 mg/L) for saquinavir. Freeze-thaw stability had a maximum overall bias of 7.4% at low QC level (0.8 mg/L) for tipranavir. Selectivity and specificity showed no interfering peaks of more than 20% of the LLOQ. CONCLUSIONS: The bioanalytical method is suitable for both TDM in stan-dard care and clinical studies. Werf T, Touw D, Alffenaar JW. Develop-ment and validation of a bioanalytical method for the simultaneous determi-nation of 14 antiretroviral drugs using liquid chromatography-tandem mass spectrometry. J Appl Bioanal 4(2), 37-50 (2018).

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: The aim was to develop and validate a LC-MS/MS assay to determine antiretrovirals in human plasma for routine therapeutic drug mon-itoring. METHODS: The selectivity, sensitivity, linearity, accuracy, precision, recovery, matrix effect, stability and dilution integrity and carry-over were validated ac-cording to EMA and FDA standards. RESULTS: For accuracy and precision, the highest overall bias was 11.3% at LLOQ of both lopinavir and saquinavir. The highest overall CV was 15.6% at the LLOQ of darunavir. Storage stability at 4°C, 20–25°C and 10°C had a maximum CV of 13.2% at low QC level (0.2 mg/L) for saquinavir. Freeze-thaw stability had a maximum overall bias of 7.4% at low QC level (0.8 mg/L) for tipranavir. Selectivity and specificity showed no interfering peaks of more than 20% of the LLOQ. CONCLUSIONS: The bioanalytical method is suitable for both TDM in stan-dard care and clinical studies. Werf T, Touw D, Alffenaar JW. Develop-ment and validation of a bioanalytical method for the simultaneous determi-nation of 14 antiretroviral drugs using liquid chromatography-tandem mass spectrometry. J Appl Bioanal 4(2), 37-50 (2018).

Key concepts: Bioanalysis, Chromatography, Liquid chromatography–mass spectrometry, Chemistry, Mass spectrometry, Tandem mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and Validation of a Bioanalytical Method for the Simultaneous Determination of 14 Antiretroviral Drugs using Liquid Chromatography-Tandem Mass Spectrometry — Research Paper | ScholarLens