2018•PLoS ONEOpen access

Influence of transducer types on bone conduction hearing thresholds

Laura Fröhlich, Stefan K. Plontke, Torsten Rahne

Open full text 18 citations

Abstract

OBJECTIVE: Different types of bone conduction transducers with different physical and electro-acoustic properties are available for audiometric hearing threshold measurements. The reference equivalent threshold vibratory force levels (RETVFL) specified in ISO 389-3 are based on measurements conducted with the B71 and KH70 transducers but apply to all types of transducers available for bone conduction audiometry. The objective of this study was to compare bone conduction hearing thresholds measured by different transducers. DESIGN: In a prospective study the hearing thresholds were measured psychometrically between 125 Hz and 8000 Hz using the Radioear B71, B81 and Präcitronic KH70 transducers. STUDY SAMPLE: Twenty-one normal hearing participants and fifteen hearing impaired participants. RESULTS: In both groups significant differences were found between the thresholds measured with the different transducers at the low frequencies 125 Hz and 250 Hz and the high frequencies 3000 Hz, 4000 Hz, 6000 Hz and 8000 Hz. In the normal hearing group, deviations from the reference threshold 0 dB HL towards lower thresholds were observed for the B71 and B81 at 125 Hz and at the high frequencies 3000 Hz, 4000 Hz, 6000 Hz and 8000 Hz. CONCLUSIONS: RETVFL-values should be reassessed and provided specifically for the different transducers.

About this research paper

What this paper is about

OBJECTIVE: Different types of bone conduction transducers with different physical and electro-acoustic properties are available for audiometric hearing threshold measurements. The reference equivalent threshold vibratory force levels (RETVFL) specified in ISO 389-3 are based on measurements conducted with the B71 and KH70 transducers but apply to all types of transducers available for bone conduction audiometry. The objective of this study was to compare bone conduction hearing thresholds measured by different transducers. DESIGN: In a prospective study the hearing thresholds were measured psychometrically between 125 Hz and 8000 Hz using the Radioear B71, B81 and Präcitronic KH70 transducers. STUDY SAMPLE: Twenty-one normal hearing participants and fifteen hearing impaired participants. RESULTS: In both groups significant differences were found between the thresholds measured with the different transducers at the low frequencies 125 Hz and 250 Hz and the high frequencies 3000 Hz, 4000 Hz, 6000 Hz and 8000 Hz. In the normal hearing group, deviations from the reference threshold 0 dB HL towards lower thresholds were observed for the B71 and B81 at 125 Hz and at the high frequencies 3000 Hz, 4000 Hz, 6000 Hz and 8000 Hz. CONCLUSIONS: RETVFL-values should be reassessed and provided specifically for the different transducers.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Different types of bone conduction transducers with different physical and electro-acoustic properties are available for audiometric hearing threshold measurements. The reference equivalent threshold vibratory force levels (RETVFL) specified in ISO 389-3 are based on measurements conducted with the B71 and KH70 transducers but apply to all types of transducers available for bone conduction audiometry. The objective of this study was to compare bone conduction hearing thresholds measured by different transducers. DESIGN: In a prospective study the hearing thresholds were measured psychometrically between 125 Hz and 8000 Hz using the Radioear B71, B81 and Präcitronic KH70 transducers. STUDY SAMPLE: Twenty-one normal hearing participants and fifteen hearing impaired participants. RESULTS: In both groups significant differences were found between the thresholds measured with the different transducers at the low frequencies 125 Hz and 250 Hz and the high frequencies 3000 Hz, 4000 Hz, 6000 Hz and 8000 Hz. In the normal hearing group, deviations from the reference threshold 0 dB HL towards lower thresholds were observed for the B71 and B81 at 125 Hz and at the high frequencies 3000 Hz, 4000 Hz, 6000 Hz and 8000 Hz. CONCLUSIONS: RETVFL-values should be reassessed and provided specifically for the different transducers.

Key concepts: Bone conduction, Transducer, Audiology, Audiometry, Absolute threshold of hearing, Acoustics, Materials science, Hearing loss

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of transducer types on bone conduction hearing thresholds — Research Paper | ScholarLens